TFM VT-222 Vortex Flowmeter User Manual
8251/x203B
Reset Totalizer
R/W
1
U8
{ 256/0x0100, "Total Flow Reset" },
Code
Type
8263/x2047
Output Pulse Unit
R/W
1
U8
{ 43, "m3" },
{ 172, "Nm3"}
{ 61, "kg" },
{ 62, "ton"},
{ 168, "Scf" },
{ 112, "cf" },
{ 40, "USGal" },
{ 42, "UKgal" },
{ 46, "bbl"},
{ 63, "lb"},
8255/x203F
Number of pulses per
unit of flow in m3
R/W
2
float
>0
8260/x2044
Work Mode
R/W
1
U8
{ 0, "F1: Anti-vibration Mode " },
{ 1, "F2: Normal Mode "
},
{ 2, "F3: Turbine Mode
},
{ 03, "F4: Test Mode "
},
8261/x2045
Temperature
and Pressure
Acquisition Mode
Setting Index
R/W
1
U8
{ 0/x000, " Pressure Manual Input,
Temperature Manual Input "},
{ 1/x001, " Pressure Manual Input,
Temperature Auto Acquisition "},
{ 16/x010, " Pressure Auto Acquisition,
Temperature Manual Input "},
{ 17/x011, " Pressure Auto Acquisition,
Temperature Auto Acquisition "},
8262/x2046
Baud Rate
R/W
1
U8
{ 0, "9600bps,8bits,1stop, No parity " },
{ 1, "4800bps,8bits,1stop, No parity " },
{ 2, "2400bps,8bits,1stop, No parity " },
{ 3, "1200bps,8bits,1stop, No parity " },
{ 4, "600bps,8bits,1stop, No parity " }
8266/x204A
Low Flow Limit
R/W
2
float
Low Flow limit.
‘Low Flow Limit’ units are in
m
3
/h.
TFM VT-222 Vortex Flowmeter Quick Manual Rev 10f page 28 of 30