,.' Connecting to the Pump:

Go to Internet Explorer, in the address line type http://viridian or

the IP address of the pump.

,.B OvervieW Page:

The overview page allows you to view the current status of the

pump.  You  may  select  the  intervals  (never,  every  30  seconds,

every 3 seconds) of which you would like the data refreshed. It dis-

plays pump operation summary information, including:

     • Power Consumption                • Heatsink Temperature

     • Amperage                                • Operating Hours

     • RPM                                         • Number of Restarts

     • Estimated Head                       • Accumulated Power

     • Estimated Flow                         Consumption

     • Estimated Efficiency                • Digital Inputs

     • Motor Status                            • Relay Status

,.4 Pump Settings:

For more detail or to change any of the pump settings click on the

Pump tab.

Limit head (Hmax)

will set the maximum allowable head.

Hmax proportional to Q

will set the ratio between head 

and flow:

Hmax = 0%: Constant pressure is set and should not exhibit

noticeable change until maximum power is reached.

Hmax = X%: Parameter will set the percentage of drop

in head from maximum to closed valve.

Limit rpm to

will limit motor speed.

Limit power to

will set maximum wattage (max power

consumption of the pump).

Limit grid current to

will assign a maximum amp draw.

Limit heatsink temperature to

will set a maximum

temperature at the heatsink (electronics area).

Switch on the relay when

can be set up as:

Standby (operation)

Active (run)

Error detected (error)

Active I2 (i2)

Input I1

is either:

Run

Run the pump (run)

Full power (max)

No function (0)

Overview

Pump

Network

Log

Help

VR 30

Limit head

adjusts the maximum pump head. The pump will try to maintain that head 

between its ports.

Hmax proportional to Q

will reduce the head at the low flow. It will drop for a set percentage at zero 

flow.

Limit rpm

can provide a head regulation similar to a manual adjustable pump.

Regulation will reduce the pump power until none of the parameters will be 

exceeded.

Regulation settings:

Limit head (Hmax) to

feet of head

Hmax proportional to Q

%

Limit rpm to

/min

Limit power to

W

Limit grid current to

A

Limit heatsink temperature to

°F

Switch on the relay when

Input I1 is: 
Input I2 is: 

 

 

 

 

 

 

   

 

   

23.0

50

3000

1600
8.0

203

error
run

max

Save

Overview

Pump

Network

Log

Help

Welcome!

You have reached 

VR 30

 circulating pump. It is connected to 

network with 

IP

 192.168.0.245 and 

MAC

 02-1A-6F-EF-FB-BA. 

Pump status is available on the right. In order to refresh the view, press 
browser's refresh button or choose automatic refresh.

Pump Status:

Refresh the view: never | every 30s | every 3s

Operation:

Power consumption: 251 W (1600 W)

Grid current: 1.09 A (8.0 A)

RPM: 1645/min (3000/min)

Estimated head: 13.1 ft. of head (13.3 ft. of head)

Estimated flow: 30.7 GPM

Estimated efficiency: 30 %

Temperatures:

Motor: OK

Heatsink: 91 °F (203 °F)

Statistics:

Operating hours: 4 h

Number of restarts: 13

Energy consumed: 1 kWh

Control:

Digital inputs: 1 (run), 0 (max)

Relay status: 0 (error)

Twin pump mode: N/A (-4)

 

 

 

 

 

 

   

 

   

Summary of Contents for Viridian 15

Page 1: ...t O rings use part number 975 001RP See detailed Motor Rotation Procedure 4 1 below Instruction Sheet Viridian 15 30 1 and 2 Models 302 364 SUPERSEDES October 24 2013 EFFECTIVE November 2 2015 A Taco resource saving product CAUTION Use supplG Wires suitaVle for x6XC ATTENTION EmploGer des fils d alimentation ade2auts pour x6XC HARNINb Do not use in sWimming pool or spa areas Pump has not Veen inve...

Page 2: ...ck up the motor with the terminals properly orientated and carefully start to slide the motor over the rotor can The resis tance of the sliding will keep the rotor and rotor can assembly in place and the screwdriver can be moved Note Do not alloW the motor to droop or the OYring might get out of position 10 Line up the bolt holes reinstall the bolts and tighten in a cross pattern 11 Carefully open...

Page 3: ...neficial when the Viridian is installed in a system where there is a much lower resis tance friction loss in the main distribution loop compared to the resistance in the transfer part of the system i e baseboard radia tion radiant floors terminal units For example this characteristic of generally lower head loss can be found in converted gravity sys tems systems operating with large temperature sp...

Page 4: ... CLOSED CLOSED CLOSED OFF RUN OPEN MAX NF 0 OPEN OPEN MAX RUN CLOSED OPEN CLOSED MAX RUN CLOSED CLOSED OPEN RUN RUN CLOSED CLOSED CLOSED RUN RUN CLOSED NF 0 MAX OPEN OPEN RUN RUN CLOSED OPEN CLOSED MAX RUN CLOSED CLOSED OPEN RUN RUN CLOSED CLOSED CLOSED MAX RUN CLOSED RUN Default MAX Default OPEN OPEN RUN RUN CLOSED OPEN CLOSED MAX RUN CLOSED CLOSED OPEN OFF RUN OPEN CLOSED CLOSED OFF RUN OPEN MAX...

Page 5: ... one pump will be connected into network each indi vidual pump should have its IP address and NetBIOS name changed and noted That will prevent network confusion and pro vide naming service in relation to pump function 1 HeV Interface Settings When the Viridian is connected to a network or another computer it can be reached by typing its IP address or NetBIOS name into the internet explorer s addre...

Page 6: ...tion Active run Error detected error Active I2 i2 Input I1 is either Run Run the pump run Full power max No function 0 Overview Pump Network Log Help VR 30 Limit head adjusts the maximum pump head The pump will try to maintain that head between its ports Hmax proportional to Q will reduce the head at the low flow It will drop for a set percentage at zero flow Limit rpm can provide a head regulatio...

Page 7: ...e the system is filled with fluid to prevent bearing damage 2 Overload trip protective shutdown Overcurrent line surge or locked rotor caused the pump to restart If the issue persists check if the rotor is spinning freely 3 Motor too hot Motor has exceeded allowed temperature and is now stopped to cool down Extremely hot medium or hardware failure might have caused that 4 Frequency converter error...

Page 8: ...le device NOR Will it ma3e the iridian accessiVle over the internet 16 1 Hireless Setting This is where it is possible to personalize the name of the wireless network The example below illustrates a network called Viridian Wireless Regardless of the wireless network name once set up the wireless device iPhone iPad PC Mac or Android device is directed to connect to that network Viridian Wireless as...

Page 9: ...uniquement a l interieur 11 Electrical Data Pump Ratings 1 phase 110 240V 47 63Hz VR15 VR20 1 phase 200 240V 47 63Hz VR25 VR30 Power Consumption HP VR15 0 027 0 680 HP VR20 0 035 1 088 HP VR25 0 054 1 496 HP VR30 0 054 2 175 HP Power Consumption W VR15 20 500 W VR20 26 800 W VR25 46 1100 W VR30 40 1600 W Rated Current 1 phase 115 230V VR15 2 2 A 6 0 A VR20 3 5 A 6 0 A Rated Current 1 phase 230V VR...

Page 10: ...0 75 100 125 150 175 200 225 250 275 300 325 350 375 400 HEAD FT 0 5 10 15 20 25 30 35 40 45 50 Flow liter min 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Head m 0 2 4 6 8 10 12 14 Performance 3 4 1 VR15 3 VR25 4 VR30 2 VR20 1 2 ...

Page 11: ...11 NOTES ...

Page 12: ...a Taco product or part or for any application restrictions consult the applicable Taco instruction sheets or contact Taco at 401 942 8000 Taco reserves the right to provide replacement products and parts which are substantially similar in design and functionally equivalent to the defec tive product or part Taco reserves the right to make changes in details of design construction or arrangement of ...

Reviews: