Taco TacoGenie 006-CT-USK Instruction Sheet Download Page 6

LIMITED WARRANTY STATEMENT

Taco, Inc. will repair or replace without charge

(at  the  company’s  option)  any  Taco  00  Series

circulator  or  circulator  part  which  is  proven

defective  under  normal  use  within  three  (3)

years from the date of manufacture.
In order to obtain service under this warranty, it

is the responsibility of the purchaser to promptly

notify the local Taco stocking distributor or Taco

in writing and promptly deliver the subject prod-

uct or part, delivery prepaid, to the stocking dis-

tributor. For assistance on warranty returns, the

purchaser  may  either  contact  the  local  Taco

stocking distributor or Taco. If the subject prod-

uct or part contains no defect as covered in this

warranty,  the  purchaser  will  be  billed  for  parts

and  labor  charges  in  effect  at  time  of  factory

examination and repair.
Any Taco product or part not installed or operat-

ed in conformity with Taco instructions or which

has been subject to misuse, misapplication, the

addition  of  petroleum-based  fluids  or  certain

chemical  additives  to  the  systems,  or  other

abuse, will not be covered by this warranty.
If in doubt as to whether a particular substance

is suitable for use with a Taco product or part, or

for  any  application  restrictions,  consult  the

applicable  Taco  instruction  sheets  or  contact

Taco at (401-942-8000).
Taco  reserves  the  right  to  provide  replacement

products and parts which are substantially similar

in design and functionally equivalent to the defec-

tive  product  or  part.  Taco  reserves  the  right  to

make changes in details of design, construction,

or arrangement of materials of its products with-

out notification.

TACO OFFERS THIS WARRANTY IN LIEU OF
ALL  OTHER  EXPRESS  WARRANTIES.  ANY
WARRANTY  IMPLIED  BY  LAW  INCLUDING
WARRANTIES  OF  MERCHANTABILITY  OR
FITNESS IS IN EFFECT ONLY FOR THE DURA-
TION  OF  THE  EXPRESS  WARRANTY  SET
FORTH IN THE FIRST PARAGRAPH ABOVE.
THE ABOVE WARRANTIES ARE IN LIEU OF
ALL  OTHER  WARRANTIES,  EXPRESS  OR
STATUTORY,  OR  ANY  OTHER  WARRANTY
OBLIGATION ON THE PART OF TACO.
TACO WILL NOT BE LIABLE FOR ANY SPE-
CIAL,  INCIDENTAL,  INDIRECT  OR  CONSE-
QUENTIAL  DAMAGES  RESULTING  FROM
THE USE OF ITS PRODUCTS OR ANY INCI-
DENTAL  COSTS  OF  REMOVING  OR
REPLACING DEFECTIVE PRODUCTS.

This  warranty  gives  the  purchaser  specific

rights, and the purchaser may have other rights

which vary from state to state. Some states do

not allow limitations on how long an implied war-

ranty lasts or on the exclusion of incidental or

consequential damages, so these limitations or

exclusions may not apply to you.

Summary of Contents for TacoGenie 006-CT-USK

Page 1: ...e Patented Integral Flow Checks IFC are built into each TacoGenie pump to prevent cold water from entering the hot water line State of the art electron ics allow the TacoGenie to accurately sense temperature and automatically shut off the pump to maximize comfort and energy savings TacoGenie saves energy and water You can look forward to over 15 years of life expectancy with a TacoGenie A Taco res...

Page 2: ...de prior to connecting the flex lines Note T s and flex lines supplied by Taco provide maximum flow and performance Alternative plumbing parts may restrict flow and delay hot water to fixtures WARNING In the event the retaining screws have been pulled out of the housing DO NOT replace them Use of any other screw may short out the stator windings creating a risk of electrical shock CAUTION When ins...

Page 3: ...existing compression ring and nut from the angle stops on the hot and cold water lines INSTALLATION FOR THE CT SERIES TACO GENIE MODELS 006 CT USK AND 008 CT USK The two custom adapter T s are designed to simplify your installation to 1 2 inch copper hot and cold supply lines If you have plumbing other than as shown in these instructions additional fittings may be required Consult a plumbing profe...

Page 4: ...operate on different voltage COMPLETING YOUR INSTALLATION 1 Turn on the water supply at the main Check the system carefully for possible leaks If leaks occur check all compression and threaded connections and tighten firmly Open hot and cold fixtures for one to two minutes to flush system completely 2 Plug in the TacoGenie to the 110V electrical outlet The pump will start automatically the first t...

Page 5: ...e sensor is loose or dislodged B The temperature sensitivity set ting now in place is too low so the pump is not shutting down soon enough Check the connection of the water temperature sensor to make sure it is firmly attached to the plug and casing Call Taco Technical Service at 1 401 942 8000 for reset information 4 Water is not hot enough when pump shuts down A The temperature sensitivity set t...

Page 6: ...r use with a Taco product or part or for any application restrictions consult the applicable Taco instruction sheets or contact Taco at 401 942 8000 Taco reserves the right to provide replacement products and parts which are substantially similar in design and functionally equivalent to the defec tive product or part Taco reserves the right to make changes in details of design construction or arra...

Reviews: