ELECTRICAL SUPPLY
A 110V electrical supply outlet is required to power the TacoGenie unit. If an outlet is not
available, install a 110V outlet in accordance with all local electrical codes.
PLUMBING INSTRUCTIONS USING USK- PLUMBING ADAPTER KIT
1. Turn off the house water supply at the main shut-off
valve.
2. Open hot and cold faucets at the fixture chosen for
installation. This will relieve water pressure from the hot
and cold water lines.
3. Remove the hot and cold shut-off valve angle stops
from the
1
⁄
2
" copper pipes located below the sink. Be
sure to use a catch basin to drain water from hot and
cold lines
For ease of installation, leave the existing compression
ring and nut from the angle stops on the hot and cold
water lines.
INSTALLATION FOR THE CT-SERIES TACO
GENIE MODELS 006-CT-USK AND 008-CT-USK
The two custom adapter “T”s are designed to simplify
your installation to
1
⁄
2
inch copper hot and cold supply
lines. If you have plumbing other than as shown in
these instructions, additional fittings may be required.
Consult a plumbing professional.
1. Turn off water supply and
remove angle stops.
2. Install tees and attach angle
stops.
4. Connect flex lines to pump.
3. Connect flex lines to tees.
CAUTION: Do not plug in the TacoGenie until all plumbing and wiring
connections are completed and water supply is turned on. Running
the circulating pump without water may damage internal components
and void warranty.
Warning: To prevent scalding, use caution
when removing valve on hot water line
.