Pre-Fab Easy Installation 

For Models: 006-CT-USK, 008-CT-USK

Installation and Operating Instructions for Existing Homes with Standard Piping

SUPERSEDES: October 8, 2015

EFFECTIVE: December 1, 2015

102-140

TacoGenie

®

is manufactured using the highest quality component parts avail-

able. Patented Integral Flow Checks (IFC

®

) are built into each TacoGenie pump

to prevent cold water from entering the hot water line. State-of-the-art electron-

ics allow the TacoGenie to accurately sense temperature and automatically shut

off the pump to maximize comfort and energy savings. TacoGenie saves energy

and  water.  You  can  look  forward  to  over  15  years  of  life  expectancy  with  a

TacoGenie.

A Taco resource – saving product

®

Instruction Sheet

www.TacoComfort.com

Plant I.D. #001-1024

Summary of Contents for TacoGenie 006-CT-USK

Page 1: ...e Patented Integral Flow Checks IFC are built into each TacoGenie pump to prevent cold water from entering the hot water line State of the art electron ics allow the TacoGenie to accurately sense temperature and automatically shut off the pump to maximize comfort and energy savings TacoGenie saves energy and water You can look forward to over 15 years of life expectancy with a TacoGenie A Taco res...

Page 2: ...de prior to connecting the flex lines Note T s and flex lines supplied by Taco provide maximum flow and performance Alternative plumbing parts may restrict flow and delay hot water to fixtures WARNING In the event the retaining screws have been pulled out of the housing DO NOT replace them Use of any other screw may short out the stator windings creating a risk of electrical shock CAUTION When ins...

Page 3: ...existing compression ring and nut from the angle stops on the hot and cold water lines INSTALLATION FOR THE CT SERIES TACO GENIE MODELS 006 CT USK AND 008 CT USK The two custom adapter T s are designed to simplify your installation to 1 2 inch copper hot and cold supply lines If you have plumbing other than as shown in these instructions additional fittings may be required Consult a plumbing profe...

Page 4: ...operate on different voltage COMPLETING YOUR INSTALLATION 1 Turn on the water supply at the main Check the system carefully for possible leaks If leaks occur check all compression and threaded connections and tighten firmly Open hot and cold fixtures for one to two minutes to flush system completely 2 Plug in the TacoGenie to the 110V electrical outlet The pump will start automatically the first t...

Page 5: ...e sensor is loose or dislodged B The temperature sensitivity set ting now in place is too low so the pump is not shutting down soon enough Check the connection of the water temperature sensor to make sure it is firmly attached to the plug and casing Call Taco Technical Service at 1 401 942 8000 for reset information 4 Water is not hot enough when pump shuts down A The temperature sensitivity set t...

Page 6: ...r use with a Taco product or part or for any application restrictions consult the applicable Taco instruction sheets or contact Taco at 401 942 8000 Taco reserves the right to provide replacement products and parts which are substantially similar in design and functionally equivalent to the defec tive product or part Taco reserves the right to make changes in details of design construction or arra...