background image

Digital 7 Day Programmable Timer:

The Plumb n’ Plug (PNP) digital timer features a large LCD
display with user friendly keys for setting time and run pro-
grams. An internal re-chargeable battery holds programmed
settings for up to 4 days during power outages.

Note: Although the Plumb n’ Plug digital timer contains
some degree of spike and electrical noise protection,
as with all electronic devices, these units can be affected
by electrical noise. It is recommended that they be
powered from a voltage source that has no switching
devices or inductive loads connected.

Technical Data:

Programs: 8 ON settings, odd numbered 1-15

8 OFF settings, even numbered 2-16

Daylight time changeover: Manual

Manual 3-way override switch: On-Auto-Off

Reserve Battery Charge: - 4 days

- Full recharge in 48 hours

Input Voltage rating: 125V, 60Hz, 15A

Clock Face Description:

Function Switches:

A. Manual Operation Switch: (I) ON, (AUTO)

Automatic, (O) OFF 

B. Programming Switch:      to set current time,

(RUN) run mode, (P) to program timer

Key Pad Selectors:

C. (P) Program Selection 

D. (OK) to confirm setting and advance to next program

E. (+) Week, Hr, Minute, Second – forward 1 unit at a

time, press & hold to scroll rapidly

F. (-) Week, Hr, Minute, Second – reverse 1 unit at a

time, press & hold to scroll rapidly

G. (         ) Skip key, to change to next screen

H. (R) To RESET timer and erase all programs

Programs:

The PNP digital timer will accept up to 16 programs. A pro-
gram consists of:

1-  ON or OFF setting

1-  Time of Day setting ( Hour, Minute & Second)

1-  Day(s) of Operation setting

Note: Each ON setting must be matched with a corre-
sponding OFF setting.

Programming your Digital Timer:

A. Setting the current time on the LCD display

1. Move Programming Switch to 

2. Press the (R) Reset key.

Clock face will display
“AM 12:00”.

3. DAY arrow will flash below the number 1 (Monday).

Press the (+) or (-) key to move arrow to the correct
day (1= Mon, 2= Tues, 7= Sun, etc), then press
(OK). HOUR will flash.

4. Press (+) or (-) to change HOUR to current time, be

sure the AM/PM symbol is correct, then press (OK).
MINUTE will flash.

5. Press(+) or (-) to change MINUTES to correct time,

then press (OK). SECONDS will flash. 

6. Since SECONDS will not be used, simply press

(OK). Your current time is set. 

7. Move Programming Switch to RUN.

B. Programming the Digital Timer ON/OFF settings

NOTE: It is helpful to write out the program timer
schedules before beginning programming. See last
page for an example.

To program timer for ON operation

1. Move Programming

Switch to (P), display
will show “-01-”. This is
your first ON setting.

2. Press (P) Program

Selection Key. Display
will read “--:--”.

G

F

H

E

D

C

A

B

AM 

12:00:

00

-01-

--:--

Summary of Contents for 265-1

Page 1: ...g on the back of the Timer box fits under the circu lator s terminal box base Adjust until the two terminal box openings are aligned 4 Secure the locknuts Feed the yellow and white circu lator lead wires into the Timer through the bushing Reassemble circulator terminal box cover and secure with the screw 5 See electrical hook up for Timer wiring Aquastat Installation Instructions 1 Disconnect the ...

Page 2: ...inute Second reverse 1 unit at a time press hold to scroll rapidly G Skip key to change to next screen H R To RESET timer and erase all programs Programs The PNP digital timer will accept up to 16 programs A pro gram consists of 1 ON or OFF setting 1 Time of Day setting Hour Minute Second 1 Day s of Operation setting Note Each ON setting must be matched with a corre sponding OFF setting Programmin...

Page 3: ...e OFF time set ting For OFF settings no light bulb will appear on the clock face Repeat the above procedure to program each ON odd number and OFF even number desired time setting in sequential order Refer to Timer Schedule below To finish and set digital timer to AUTO operation 1 When all programs are completed move Programming Switch P to RUN position 2 Move Manual Operation switch to AUTO Timer ...

Page 4: ...dition of petroleum based fluids or certain chemical additives to the systems or other abuse will not be covered by this warranty If in doubt as to whether a particular substance is suitable for use with a Taco product or part or for any application restrictions consult the applicable Taco instruction sheets or contact Taco at 401 942 8000 Taco reserves the right to provide replacement products an...