4 - Seatrial and Calibration
Once the Micronet Instrument system has been installed on the vessel
and Autonetworking has been completed it is necessary to carry out
calibration.
It is not safe to use the instruments for navigational purposes
until calibration has been carried out correctly.
Wind Calibration
Both Wind Speed and Direction can be calibrated to ensure that
readings from the Wind Transmitter are displayed accurately.
4.1.1 Wind Angle Offset
Motor the vessel directly into the wind.
Press and hold the
button for 2 seconds to enter Setup
Press the
button repeatedly to scroll to the “SETUP/WIND”
Chapter
Press the
button to advance to “WIND/+0000” Page
Press the
button to enter Edit Mode
Press the
or
buttons to change the displayed value to 000.
The bottom digits will indicate the number of degrees of offset
entered.
Press the
button to exit Edit Mode
Press and hold the
button to exit Setup and return to normal
operation.