- 15 -
4.2.8 DC current
- Overload protection: protective tube for mA measuring range (FF600mA/250V) ; protective tube
for 10A measuring range (FF10A/250V) .
- Maximal input current: mA position: 600mA DC/AC (valid value);
- 10A position: 10A DC/AC (valid value)
- When the measured current is over 5A, the duration of continuous measurement shall not be over
10 seconds. The current measurement shall be carried out 1 minute after the completion of previous
measurement.
4.2.9 AC current
- Overload protection: protective tube for mA measuring range (FF600mA/250V) ; protective tube
for 10A measuring range (FF10A/250V) .
- Maximal input voltage: mA position: 600mA DC/AC (valid value);
- 10A position: 10A DC/AC (valid value)
- When the measured current is over 5A, the duration of continuous measurement shall not be over
15 seconds. The current measurement shall be carried out 1 minute after the completion of previous
measurement.
- Frequency response: 40Hz-1kHz True RMS
4.2.10 Temperature (depends on different model, only for the instruments with it)
- Overload protection: 600V DC/AC
Measuring range
60µA
6mA
60mA
600mA
10.00A
Resolution
0.01µA
0.001mA
0.01mA
0.1mA
10mA
Accuracy
±(0.8% R 3 digits)
±(1.2% R 3 digits)
Measuring range
60mA
600mA
10A
Resolution
0.01mA
0.1mA
10mA
Accuracy
±(1% R 3 digits)
±(1.5% R 3 digits)
Measuring range
℃
℉
Resolution
1
℃
1
℉
-20
℃
~1000
℃
-4
℉
~ 1832
℉
± (1.0%+3) reading
± (1.0%+3) reading
Accuracy
Summary of Contents for DM01M
Page 1: ...DIGITAL MULTIMETER User Manual...
Page 2: ...Contents English 01 16 Italiano 65 80 Deutsch 17 32 Fran ais 33 48 Espa ol 49 64...
Page 6: ...04 Physical appearance Fig 1 Display panel 2 2 Description of the symbols on the display unit...
Page 22: ...20 Physical appearance Fig 1 Display panel 2 2 Beschreibung der Symbole...
Page 70: ...68 Aspetto fisico Figura 1 Display pannello 2 2 Descrizione dei simboli sul display...