background image

TAB d.d., Polena 6, SI-2392 Mezica, Slovenia  

Tel: +386 2 87 02 300    Web: www.tab.si     E-mail: [email protected]

P U R E   E N E R G Y ,   M A X I M U M   P O W E R

R2428_Operating_Manual_13.05.2021.indd   24

R2428_Operating_Manual_13.05.2021.indd   24

17.5.2021   11:35:52

17.5.2021   11:35:52

Summary of Contents for R2428

Page 1: ...www tab si Lithium Ion Phosphate Energy Storage System R2428 Operation Manual R2428_Operating_Manual_13 05 2021 indd 1 R2428_Operating_Manual_13 05 2021 indd 1 17 5 2021 11 35 42 17 5 2021 11 35 42...

Page 2: ...R2428_Operating_Manual_13 05 2021 indd 2 R2428_Operating_Manual_13 05 2021 indd 2 17 5 2021 11 35 42 17 5 2021 11 35 42...

Page 3: ...3 1 Schematic Diagram of Solution 12 3 2 Explanation of Symbol 13 3 3 Tools 13 3 4 Safety Gear 14 4 Installation 14 4 1 Package Items 14 4 2 Installation Location 16 5 Trouble Shooting Steps 20 5 1 Pr...

Page 4: ...uchable area Warning electric shock Warning Fire Do not place near flammable material Read the product and operation manual before operating the battery system Grounding Recycle label The certificate...

Page 5: ...ething abnormal 7 Do not use cleaning solvents to clean battery 8 Do not expose battery to flammable or harsh chemicals or vapors 9 Do not paint any part of battery include any internal or external co...

Page 6: ...t is prohibited to connect the battery with different type of battery 3 It is prohibited to put the batteries working with faulty or incompatible inverter 4 It is prohibited to disassemble the battery...

Page 7: ...environmentally friendly Cathode material is made from LiFePO4 with safety performance and long cycle life Battery management system BMS has protection functions including over dis charge over charge...

Page 8: ...ischarge Current A 85 Peak Charge Discharge Current A 100A 15sec Communication RS485 CAN Configuration max in 1 battery group 20pcs Working Temperature 0 C 55 C Charge 10 C 55 C Discharge Shelf Temper...

Page 9: ...ail Please check below table LED Indicators Instructions for the detailed definition Protection Protection light RED LED to show the battery is under BMS protection Combine with SOC LEDs to show which...

Page 10: ...age Discharge MOS OFF Possible reason discharging over current Low Voltage Short circuit Reverse polarity Charge and discharge MOS all OFF Possible reason Over Low Temperature MOS Over Temperature BMS...

Page 11: ...Terminal RJ45 port follow TAB Low voltage CANBUS protocol for communication between master battery and host equipment Definition of RJ45 Port Pin No RS485 Pin CAN Pin 1 2 GND 3 4 CAN H 5 CAN L 6 7 RS...

Page 12: ...power plug BMS function Protection and Alarm Management and Monitor Charge Discharge Cut off Cells Balance Charge Over Voltage Intelligent Charge Model Discharge Under Voltage Capacity Retention Calc...

Page 13: ...Use properly insulated tools to prevent accidental electric shock or short circuits If insulated tools are not available cover the entire exposed metal surfaces of the available tools except their ti...

Page 14: ...n 4 1 Package Items Unpacking and check the Packing List 1 For battery module package Two power cables and one communication cable for each battery package Grounding cable Grounding cables use 10AWG y...

Page 15: ...modules 2 For battery system connects to inverter Two long power cables max current capacity 120A and one communication cable for each energy storage system NOTE These three long cables are NOT in bat...

Page 16: ...d humidity are maintained at a constant level There is minimal dust and dirt in the area CAUTION If the ambient temperature is out of the operating range the battery pack stops operating to protect it...

Page 17: ...he cabinet follow below picture 2 Fix each module with the cabinet with 4 screws 3 Connect the cables between battery modules including grounding cables follow below picture 17 R2428_Operating_Manual_...

Page 18: ...power cable connect as A D or B C donot connect as A B or C D to avoid unbalancing current transmitted For 2 pairs of external power cable connect as A D and B C For more than 2 pairs of external cab...

Page 19: ...er Battery Module others are slaves 1 master battery configure with maximum 19 slave batteries 4 Press the Start Button SW of master battery to power on all the battery LED light will be on after mast...

Page 20: ...e LED Indicators Instructions to check a Over Low temperature Above 55 C or under 10 C the battery could not work Solution turn off the battery module move battery to the normal operating tem perature...

Page 21: ...on Ingestion Induce vomiting and seek medical attention 2 Fire NO WATER Only dry powder fire or carbon dioxide extinguisher can be used if possible move the battery pack to a safe area before it catch...

Page 22: ...R2428_Operating_Manual_13 05 2021 indd 22 R2428_Operating_Manual_13 05 2021 indd 22 17 5 2021 11 35 50 17 5 2021 11 35 50...

Page 23: ...R2428_Operating_Manual_13 05 2021 indd 23 R2428_Operating_Manual_13 05 2021 indd 23 17 5 2021 11 35 50 17 5 2021 11 35 50...

Page 24: ...a Slovenia Tel 386 2 87 02 300 Web www tab si E mail info tab si P U R E E N E R G Y M A X I M U M P O W E R R2428_Operating_Manual_13 05 2021 indd 24 R2428_Operating_Manual_13 05 2021 indd 24 17 5 20...

Reviews: