Operation Manual

TW-6 

Please press the 

FUNKTION

 button to switch between the following functions:

Measur

• 

 – measure function: takes measurements;

Subst

• 

 - ubstance function: allows to choose the measured material

Memory

• 

 – memory function: recalls the stored measurement values;

REF PT

• 

 – reference point function: sets the reference point;

Off

• 

 – off function: switches the device off;

Delete

• 

 – delete function: deletes the stores measurement values;

Zero

• 

 – zeroing function: calibrates the device;

Resol.

• 

 – resolution function: switches between the measurement resolution;

Soft

• 

 indicates the installed software version.

To select a function please press the 

OK [MENU]

 button.

Measure function - 

Measur

After You select this function the display will show the 
currently selected material, e.g. 

Zn/Al

 and the battery 

indicator in the first line and 

----um

 in the second. The 

gauge is ready to take measurement.

After You put the sensor against the body of the car the 
result of the measurement will be shown in the second 
line.To  store  the  result  please  press  the 

OK  [MENU]

 

button  when  taking  the  measurement.  A 

*

  symbol 

appears next to the shown value. 

WARNING! 

T

he

 

cApAcITy

 

of

 

The

 

devIce

s

 

memoRy

 

Is

 100 

ResulTs

. N

exT

 

sToRAGes

 

WIll

 

deleTe

 

The

 

oldesT

 

oNes

.

140um

Zn/Al

*

140um

Summary of Contents for TW-6

Page 1: ...Thoma Tel Fax 48 95 741 11 62 info t4w eu www t4w eu Coating Thickness Gauge TW 6 Operation Manual a r t n r 5 9 2 4 8...

Page 2: ...peration Manual TW 6 Table of contents 1 Technical specifications 3 2 Getting started 3 3 Gauge manual 4 Guarantee TW 6 9 The price of this product includes the recycling fee of 0 10 PLN Before You st...

Page 3: ...ent is made The memory doesn t get deleted after turning off the device although it is possible to delete it from the menu The device has a LCD backlight which makes measuring in places with insuffici...

Page 4: ...nstead of a alkaline battery You can use a compatible fully charged accu 3 If the device seems to work improperly it can be caused by an empty battery or accu To take a measurement please put the devi...

Page 5: ...ion function switches between the measurement resolution Soft indicates the installed software version To select a function please press the OK MENU button Measure function Measur After You select thi...

Page 6: ...ed You have the following possible choices galvanized steel aluminium Zn Al steel Fe reference point Ref You can switch between the sheet materials with the FUNKTION button to accept the selection pre...

Page 7: ...means that the gauge is well calibrated Should the aberration be larger than 0 10 m please put the sensor once more against of the calibration sheet wait until the result stabilizes and press the OK M...

Page 8: ...choose between 2 measurement resolutions chosen with the FUNKTION button D 10 the measurement is rounded up to 10 m faster D 1 the measurement is accurate up to 1 m precise For car paint coating thic...

Page 9: ...be shipped to the Producer it happens on the shipper s responsibility and cost 8 The device will be not accepted by the Service if pt 6 is not kept if the defect is of no workmanship or 9 material nat...

Reviews: