General

General

We strongly recommend that you read this user manual before using LineCrypt.

Deutsche Telekom cannot be held liable for any possible damage caused to

the device or other facilities arising from the failure to follow the instructions in

this manual. 

Overview of pictorial symbols

Safety symbol to warn against danger for people and property is identified with

a triangular warning sign.  

Important messages for data security are identified with the hand icon.

Important messages for operation of the LineCrypt DSL are identified with the

bulb icon.

Safety notes

Do not open the LineCrypt. By opening the four screws on the base of the

housing you may endanger the user and any warranty claim will be waived.

Allow no liquids to seep into the LineCrypt.

Assemble the device as described in the section “Assembly”.

Do not plug in or detach any connections to the LineCrypt during a thunder-

storm.

The LineCrypt is only intended for use in dry indoor areas. 

Lay the cables in such a way that they cannot be stood on or tripped over by

anyone.

Before any maintenance work on the LineCrypt pull out the mains plug. 

3

Summary of Contents for LineCrypt DSL

Page 1: ...T TeleSec LineCrypt DSL User s Guide...

Page 2: ...Safety notes 3 Power failure 4 Function Overview 5 Assembly 6 Included in delivery 6 Preparation 7 Installation place 11 Start Up 12 CD configuration software 12 Operation 13 LED on the top side 13 LE...

Page 3: ...2 Registered trademarks trademarks and service names are used in this manual Even if they are not marked as such the relevant protection regulations apply IDEATM is a trademark of Ascom Systec AG...

Page 4: ...the hand icon Important messages for operation of the LineCrypt DSL are identified with the bulb icon Safety notes Do not open the LineCrypt By opening the four screws on the base of the housing you...

Page 5: ...ct the device to a freely accessible earthed socket so that you can pull out the mains plug without delay when required Power failure The configuration remains unchanged in case of a power failure The...

Page 6: ...SL transfers the encrypted data through an IP Tunnel In this way two or more LineCrypt in an unprotected network allow a protected Virtual Pri vate Network VPN to be set up The LineCrypt DSL can set u...

Page 7: ...ur internal network or your PC Included in delivery Open the packaging and check that the contents is complete 1 LineCrypt DSL with mains cable and Chip card 1 Crossed Ethernet connection cable with R...

Page 8: ...k card the following applies for the cable to be used Use a crossed cable when connecting to a network card e g PC Use an uncrossed cable when connecting to a hub or an Ethernet switch Contact Line 1...

Page 9: ...card enc at end of number or you can read it with the help of a PC and the configuration software from the LineCrypt Fig 4 Chip card type NetKey Card with certificate number 991715387 To remove the C...

Page 10: ...he cover horizontally until the limit stop approx 9 mm and then lift it up To remove the Chip card pull the card lock out Fig 6 Removing the cover Now remove the Chip card and note the Certificate ID...

Page 11: ...rd installation If the Chip card should remain permanently in the LineCrypt DSL put the card lock back into its operational position Assemble the cover to the device and fix it with the screw 10 Card...

Page 12: ...rilling template and mount the LineCrypt with the sockets on the underside The installation place should be dry and free from dust The Li neCrypt is designed for an environmental temperature range of...

Page 13: ...other LineCrypt equipment or unencrypted connections with other Ethernet devices a corre sponding configuration of the LineCrypt DSL is required Use the provided PC program lcc to configure the LineC...

Page 14: ...een light No Chip card plugged in Orange light Valid Chip card plugged in Orange blinking 1x Authorization file configuration missing 2x 3x 4x 5x Problem with the Chip card Recovery Plug Chip card in...

Page 15: ...rear side there are four LED Two of the LED green and yellow provide information about the status of the peer Ethernet interface and have the follow ing meaning Yellow The Ethernet connection is inta...

Page 16: ...41 F to 104 F 4 C to 50 C Ethernet interface Ethernet interfaces 2 x 10BaseT 10 Mbps half duplex full duplex with Western RJ45 WE8 8 sockets PC interface V 24 Mini DIN 8 Chip card T TeleSec NetKey Ca...

Page 17: ...ematic diagram of possible connection variants E EMC Electromagnetic compatibility The ability of an appliance installation or system to function satisfactorily in the electromagnetic environment with...

Page 18: ...e communication partners At the start of the tunnel all data packets receive an additional header that refers to the tunnel end Here the external frame is removed and the original data packet is forwa...

Page 19: ...the IP protocol supports the functions of the transport layer and establishes a secure connection be tween the entities before data transfer TCOS TeleSec Chip card Operating System Operating system f...

Page 20: ...ard 6 8ff 13 15 18 Connection scheme 6 16 drilling template 11 Environmental temperature 15 Ethernet 6f 12 14ff IDEA 15 IP Network 17 IP Tunnel 5 17 LAN 17 LED 13 17 NetKey Card 13 15 17 Operating Sys...

Page 21: ...ble for content T TeleSec Products Further information Internet http www telekom de t telesec e mail T Telesec telekom de Issued by Deutsche Telekom AG Edition 04 04 03 Subject to change without notic...

Reviews: