  SECTION 2    KEYBOARD AND DISPLAY                                                   

 

2. 1 DESCRIPTION OF KEYS 

ON/OFF

: power switch, use this key to turn on and turn off scale 

ZERO

:  re-zero  key,  use  this  key  to  return  zero  reading,  when  in  setting 

mode, use this key to sure setting. 

TARE

:  use  the  tare  key  to  subtracts  tare  values  and  changes  the  scale 

from gross mode (no tare) to net mode. In the setting mode, this key 
is used to increase the value. 

HOLD

:  reading  lock  key,  use  this  key  to  lock  reading,  in  calibrate  mode, 

use this key to change decimal point. 

UNIT

: Press the key, the scale can to select units. It has two units, kg and 

lb.     

When you weigh, press this key, you can see the conversion of the 

units. 

when in setting mode, use this key to escape setting 

2.2 Remote controller key function(30kg without this function): 

            1.TARE      2. ZERO      3.UNIT      4.HOLD

 

           

 
 
 
 
 
 
 
 

2.3 

DISPLAY 
BATT.

: battery indicator. The battery should be 

charged when the symbol is on. The scale will 

still operate for about 30 minutes after which it will automatically switch off 
to protect the battery.

 

Zero

: zero indicator, when this indicator on, scale in zero point. 

Tare

: tare indicator, this indicator on means current weight is the net weight, 

which has been subtracted the tare values. you can press the TARE key to 
return gross weight mode. 

Hold

:  lock  indicator,  when  this  indicator  on,  scale  in  reading  data  lock 

mode, you can press HOLD key to return normal weighing mode 

Kg.

: weighing unit, kilogram. 

lb.

: weighing unit, pound.

 

 

Summary of Contents for DR Series

Page 1: ...www scalesearch co uk UGDR E0 01 DR series Hanging Scales technical guide...

Page 2: ......

Page 3: ...Descriptions of keys 3 2 2 Display 3 SECTION 3 OPERATION 5 3 1 General instruction 5 3 2 Basic operation 5 3 2 1 ON OFF 5 3 2 2 Zero the scale 5 3 2 3 Reading lock 5 3 2 4 Overload warning 5 SECTION 4...

Page 4: ......

Page 5: ...tpoint control Power saving mode Remote control included with control distance 20 m One charge can be lasting up to 35 hours Low power indication and auto power off 1 2 SPECIFICATIONS Model DR 30 DR 6...

Page 6: ......

Page 7: ...www scalesearch co uk 1 3 DIMENSION Different with 30kg...

Page 8: ...u can see the conversion of the units when in setting mode use this key to escape setting 2 2 Remote controller key function 30kg without this function 1 TARE 2 ZERO 3 UNIT 4 HOLD 2 3 DISPLAY BATT bat...

Page 9: ...ERATION 3 2 1 Power on and off Please press ON OFF key before you operate this scale and press ON OFF key again after you operate this scale 3 2 2 Zero the scale When there is no item on the scale but...

Page 10: ...automatically switch off to protect the battery 4 The battery should be charged for 12 hours for full capacity 5 Just on the right side of the display these is an LED to indicate the status of batter...

Page 11: ...ey to move the active digit use TARE key to increment a digit after input calibrate mass weight press ZERO key to sure display show LOAD add calibrate mass on hook after Hold indicator on press ZERO k...

Page 12: ...without this function Inc 5 Inc 10 inc 5 F3 a2n Set zero tracking range 30kg without this function 0 5d 0 5d 1d 1d 2d 2d 4d 4d 1d F4 Flt Set filter range 30kg without this function FLT 1 fast FLT 2 F...

Page 13: ...www scalesearch co uk F8 cal Calibrate Uload calibrate weight load complete See detail at SECTION 5...

Page 14: ...ain Err 5 Keyboard Error Keyboard short please check the key wire whether the key have mechanical problem Err 6 A D out of range The values from the A D converter are outside the normal range Remove w...

Reviews: