![T-MAG AMX Series Engineering, Operation & Maintenance Download Page 5](http://html2.mh-extra.com/html/t-mag/amx-series/amx-series_engineering-operation-and-maintenance_3080165005.webp)
MAG-DRIVE
SPECIALTY CODES
S e c t i o n 2
D E S I G N A T I O N S Y S T E M
LEGEND
TMXXX / XX / XX / XXX / XX /
XXX
MOTOR
VOLTAGE
MAG-DRIVE
PUMP
IMPELLER DIAMETER
O-RINGS / GASKETS
BEARING
PUMP
SIZE
CASING MATERIAL
SPECIALTY
CODE
(if applicable)
BEARING/BUSHING DETAIL*
Bearing
Shaft
Wear Ring
Front Thrust Ring
Rear Thrust Ring
C
Carbon
995 Al Ceramic
Carbon
995 Al Ceramic
995 Al Ceramic
R
Rulon
995 Al Ceramic
Rulon
995 Al Ceramic
995 Al Ceramic
A
995 Al Ceramic
995 Al Ceramic
Rulon
995 Al Ceramic
995 Al Ceramic
S
Sintered Sic
Sintered Sic
Sintered Sic
Sintered Sic
Sintered Sic
MATERIAL CODES
NOTE:
For IEC B5 frame motors,
replace “C” with “E” in the pump
size designation. See chart below
for E-Frame configuration.
SIZE
FRAME
1/2 HP
D71D
1 HP
D80D
2 HP
D905D
3 HP
D90LD
5 HP
DF112MD
NOTE:
All pump flanges are ANSI, DIN and JIS Combination
*C is the standard bearing/bushing configuration as this is the only configuration with the dry-run option
+ Pump head only is a complete wet end kit with no motor, no mounting bracket, no outer magnet and no base.
**VT is the standard elastomer.
PUMP SIZE
4HC = 1-1/2" (38mm) Inlet and
Discharge, 1/2 HP (0.40 kW),
C-Face Mount,
56C Frame
4KC = 1-1/2" (38mm) Inlet and
Discharge, 1 HP (0.75 kW),
C-Face Mount,
56C Frame
6LC = 2" (51mm) Inlet, 1-1/2"
(38mm) Discharge, 2 HP
(1.50 kW), C-Face,
145TC Frame
6MC = 2" (51mm) Inlet, 1-1/2"
(38mm) Discharge, 3 HP
(2.20 kW), C-Face Mount,
145TC Frame
6NC = 2" (51mm) Inlet, 1-1/2"
(38mm) Discharge, 5 HP
(3.70 kW), C-Face Mount,
184TC Frame
10NC = 2-1/2" (64mm) Inlet, 2"
(51mm) Discharge, 5 HP
(3.70 kW), C-Face Mount,
184TC Frame
CASING MATERIAL
P =
GLASS-FILLED
POLYPROPYLENE - BLACK
E = CONDUCTIVE ETFE - BLACK
BEARING*
C = CARBON
R = RULON* (FILLED PTFE)
A = 995 CERAMIC (AL2O3)
S = SINTERED
SiC
O-RINGS / GASKETS**
VT = VITON
ND = EPDM
IMPELLER DIAMETER
FULL TRIM IN MM SHOWN
NOTE:
:
1)
Standard orders are shipped
with impellers that have not been
trimmed and are at maximum size.
2)
All impeller diameters shown in
“mm” size and are variable in one
(1) millimeter increments.
3)
Proper impeller selection is
determined by the system
parameters. Consult factory
for details.
4) Proper impeller size is effected by
motor rpm.
5)
Orders for units with trimmed
impeller will be changed out at the
factory before shipment.
MOTOR VOLTAGE
AA = 110/220V -
1 PHASE - 60 HZ - TEFC
BA = 208-230/460V 3 PHASE -
60 HZ – TEFC
CA = 575V 3 PHASE - 60 HZ - TEFC
XX = SPECIAL MOTOR
(CONSULT FACTORY)
YY = PUMP HEAD ONLY
+
ZZ = NO MOTOR, WITH
MOUNTING BRACKET
AND OUTER MAGNET
3
TF = TEFLON ENCAP. VITON
Summary of Contents for AMX Series
Page 29: ...27 N O T E S...