23
Step 10
Once the set screws are removed,
inspect the shaft keyway and bell
housing for wear or damage and
replace as necessary.
Step 11
Carefully remove the pump shaft
from the front shaft support.
DO NOT twist or flex the shaft to
assist removal. Pull vertically to free
the shaft from the front support.
Step 12
Gently lift up on the front buffer
to free it from the inlet port.
DO NOT use any tools for removal
as this may damage the part forcing
replacement.
Step 13
Gently lift up on the front shaft
support to free it from the pump
inlet port. DO NOT use any tools
as this may damage the part
forcing replacement.
Step 14
If the inlet or discharge flanges are
worn or damaged, remove and
replace the flange and o-ring. Use
a strap wrench or soft jawed vise
for removal of the old flange and
installation of the new one.