6
To avoid any hazard, any further disassembly as well as the replacement of parts must only be done by the
manufacturer or a by an authorised service provider.
Water left in the pump may freeze in case of frost and thus cause considerable damage. Therefore, the pump
must be removed from the liquid being discharged and fully drained when temperatures are below the freezing
point of the liquid. Please store the pump in a dry, frost-protected place.
In the case of malfunction, you should first of all check whether it was caused by an operating error or some other
reason which cannot be attributed to a defect of the device - for instance a power failure.
The list below shows some possible malfunctions of the device, possible causes and tips on their elimination. All
the measures referred to may only be carried out with the pump being separated from the electrical mains. If you
yourself feel unable to eliminate any of these malfunctions, please contact the customer service department or
your point of sales. Any repair beyond the scope specified below must only be performed by qualified staff.
Please bear in mind that all warranty claims will become void in the case of damage caused by inappropriate
repair attempts, and that we decline any liability for any ensuing damage.
MALFUNCTION
POSSIBLE CAUSE
ELIMINATION
1. The pump is not
discharging any liquid, the
motor is not running.
1. No current.
2. Thermal motor protection feature has
triggered.
3. The capacitor is defective.
4. The pump wheel is blocked.
5. The floating switch is blocking (in
automatic operation).
6. The floating switch is defective (in
automatic operation).
1. Please use a device complying with
GS (German technical supervisory
authority) to check for the presence of
voltage (safety information to be
observed!). Please verify the correct
position of the plug.
2. Separate the pump from the electrical
mains, allow the system to cool down,
eliminate cause.
3. Please contact the customer service
department.
4. Eliminate blocking of pump wheel.
5. Unblock or clean floating switch.
6. Please contact the customer service
department.
2. The motor is running, but
the pump is not discharging
any liquid.
1. The intake openings are clogged.
2. The pressure line is clogged.
3. Air penetrates into the pump body.
4. The min. suction level was fallen
short of (in automatic operation).
1. Remove possible congestion.
2. Remove possible congestion.
3. Start pump several times so that the
entire air will be driven out.
4. Make sure that the minimum suction
level is not fallen short of; if necessary,
adjust floating switch properly or make
sure that it can move freely; in the case
of a defective floating switch, please
contact customer service.
3. The pump stops after a
short time of operation
because the thermal motor
protection feature has
triggered.
1. The electrical supply does not
correspond to the information given on
the type plate.
2. Pump or intake openings are blocked
by solids.
3. Liquid is too viscous.
4. Temperature of the liquid is too high.
5. Pump is running dry.
1. Please use a device complying with
GS (German technical supervisory
authority) to check the voltage of the
lines of the connection cord (safety
information to be observed!).
2. Remove possible congestion.
3. Pump may not be suitable for this
liquid. If feasible, the liquid should be
thinned.
4. Make sure that the temperature of the
liquid being pumped does not exceed
the max. admissible value.
5. Eliminate causes of dry-running.
4. Intermittent or irregular
operation.
1. Refer to section 1.4.
2. Refer to section 3.3.
3. Refer to section 3.4.
4. Mains voltage out of tolerance.
5. Motor or pump wheel defective.
1. Refer to section 1.4.
2. Refer to section 3.3.
3. Refer to section 3.4.
4. Make sure that mains voltage matches
that indicated on the type plate.
5. Please contact the customer service
department.
5. Water quantity discharged
by pump is inadequate.
1. Refer to section 2.1.
2. Refer to section 2.2.
3. Worn pump wheel.
1. Refer to section 2.1.
2. Refer to section 2.2.
3. Please contact the customer service
department.
14
Summary of Contents for I-COMPAC 13000
Page 48: ...1 T I P 1 1 2 2 3 2 4 3 5 3 6 4 7 4 8 5 9 7 10 8 11 8 1 RCD FI 30 mA 8 46...
Page 50: ...3 4 5 5 1 5 2 10 33 25 1 25 33 33 mm a 33 25 mm 1 b 33 mm 5 3 5 4 48...
Page 51: ...4 6 Fl 30 mA DIN VDE 0100 739 VDE H05RN F 3 x 1 0 mm 7 7 1 Auto 49...
Page 52: ...5 230 V 7 2 Manual 230V 7 3 T I P I Compac 8 8 4 9 3 4 50...
Page 53: ...6 I II II IV V 1 1 2 3 4 5 6 1 GS 2 3 4 5 6 51...
Page 55: ...8 a 1 2 10 www tip pumpen de 11 PDF service tip pumpen de EU EU 2012 19 EU 53...
Page 102: ...Notizen notes note notas...
Page 103: ...Notizen notes note notas...