background image

 

 

 

Dear customer, 

Congratulation for buying your new device from T.I.P.! 

Like all our products, this one, too, was developed using the latest technological knowledge. The device was 

manufactured and assembled on the basis of state-of-the-art pump technology using most reliable electrical or 

electronic components which ensure a high level of quality and a long life of your new product. 

Please read through these operating instructions carefully to make sure that you can fully benefit from all features. 

Some explanatory illustrations can be found at the end of these operating instructions. 

We hope you will enjoy your new device! 

 

Table of contents 

 

1.

 

General safety information

 

 ............................................................................................................................. 1

2.

 

Technical Data

 

 ............................................................................................................................................... 2

3.

 

Range of use

 

 .................................................................................................................................................. 2

4.

 

Scope of delivery

 

 ........................................................................................................................................... 3

5.

 

Installation

 

 ...................................................................................................................................................... 3

6.

 

Electrical connection

 

 ...................................................................................................................................... 4

7.

 

Putting into operation

 

 ..................................................................................................................................... 5

8.

 

Automatic operation / anti dry running protection

 

 ........................................................................................... 5

9.

 

Maintenance and troubleshooting

 

 .................................................................................................................. 6

10.

 

Warranty

 

 ........................................................................................................................................................ 7

11.

 

How to order spare parts

 

 ................................................................................................................................ 8

12.

 

Service

 

 ........................................................................................................................................................... 8

         Annex: Illustrations 

 

 

1.  General safety information 

 

Please read through these operating instructions carefully and make yourself conversant with the control 

elements and the proper use of this product. We shall not be liable in the case of damage caused as a result of 

the nonobservance of instructions and provisions of the present operating instructions. Any damage caused as a 

result of the nonobservance of the instructions and regulations contained in the present operating instructions 

shall not be covered by the warranty terms. Please keep these operating instructions in a safe place and hand 

them on together with the device should you ever dispose of it. 

Persons not conversant with the contents of these operating instructions must not 

use this device. 

 

This appliance can be used by children aged from 8 years and above and persons 

with reduced physical, sensory or mental capabilities or lack of experience and 

knowledge if they have been given supervision or instruction concerning use of the 

appliance in a safe way and understand the hazards involved. Children shall not play 

with the appliance. Cleaning and user maintenance shall not be made by children 

without supervision.  

 

The pump must not be used when people are in the water. 

 

The pump must be supplied through a residual current device (RCD) having a rated 

residual operating current not exceeding 30mA. 

 

If the supply cord is damaged, it must be replaced by the manufacturer, its service 

agent or similarly qualified persons in order to avoid a hazard. 

 

Notes and instructions with the following symbols require particular attention: 

 

 

 

Any nonobservance of these instructions involves the danger of bodily harm to people and/or 

damage to property. 

 

 

Any nonobservance of this instruction bears the risk of an electrical shock which may cause 

damage to persons or property. 

9

Summary of Contents for AJ 4 Plus 100/57 AUT

Page 1: ...Gebrauchsanweisung Tiefbrunnenpumpe 01 Operating Instructions Deep spring pump 09 AJ 4 Plus 100 57 AUT...

Page 2: ...n e uveden ch sm rnic EU a v ech n sleduj c ch zm n 2006 95 EC 2004 108 EC 2009 125 EG 2011 65 EU EU izjava o sukladnosti Mi firma T I P Technische Industrie Produkte GmbH Siemensstr 17 D 74915 Waibst...

Page 3: ...Missach tung von Anweisungen und Vorschriften dieser Gebrauchsanweisung verursacht werden Sch den in Folge einer Missachtung von Anweisungen und Vorschriften dieser Gebrauchsanweisung fallen nicht unt...

Page 4: ...benen Maximalleistungen wurden ermittelt bei freiem unreduziertem Auslass 2 1 Informationen gem Richtlinie 2009 125 EG 2 Mindesteffizienzindex MEI ist eine dimensionslose Gr e f r den hydraulischen Pu...

Page 5: ...e Verpackung nach M glichkeit bis zum Ablauf der Garantiezeit auf Entsorgen Sie Verpa ckungsmaterialien umweltgerecht 5 Installation 5 1 Allgemeine Hinweise zur Installation W hrend der gesamten Insta...

Page 6: ...ie Pumpe muss vollst ndig in die Fl ssigkeit eingetaucht werden Der Abstand zum Grund sollte im Betrieb mindestens 0 5 m betragen um das Ansaugen von Schlamm Sand Steinen etc zu verhindern Um diese Po...

Page 7: ...Motorschutz Bei berlastung schaltet sich der Motor selbst aus und nach erfolgter Abk hlung wieder an M gliche Ursachen und deren Behebung sind im Abschnitt Wartung und Hilfe bei St rf llen genannt 8...

Page 8: ...an zubringen Abb 4 Jede weitere Demontage und das Ersetzen von Teilen darf nur durch den Hersteller oder ei nen autorisierten Kundendienst erfolgen um Gef hrdungen zu vermeiden Demontage Montage Bei...

Page 9: ...s Ger t gekauft wurde Die Garantiezeit beginnt mit dem Tag des Kaufs zu nachfolgenden Bedingungen Innerhalb der Garantiezeit werden alle M ngel die auf Material oder Herstellungsfehler zur ckzuf hren...

Page 10: ...ich bitte an T I P Technische Industrie Produkte GmbH Reparaturservice und Ersatzteilversand Siemensstra e 17 D 74915 Waibstadt Tel 49 0 7263 9125 0 Fax 49 0 7263 9125 25 E Mail service tip pumpen de...

Page 11: ...instructions Any damage caused as a result of the nonobservance of the instructions and regulations contained in the present operating instructions shall not be covered by the warranty terms Please k...

Page 12: ...int as well as with partial loading and overloading The MEI reference value for water pumps with the best operating efficiency is 0 70 Information on the efficiency reference value can be found under...

Page 13: ...manner 5 Installation 5 1 General installation information During the entire process of installation the device must not be connected to the electrical mains The pump and the entire connection system...

Page 14: ...iquid to be discharged Make sure that the unit will not bump or rub against the circumference of the cavity The unit must be fully immersed in the liquid The minimum distance from the ground should be...

Page 15: ...ually be found in clogged or leaking intake lines or a lack of liquid to be discharged In this context please note that the water level may vary as a result of the withdrawal of water weathering influ...

Page 16: ...the water If this external cleaning is not sufficient then the stainless steel filter panel 4 can be removed from the pump by loosening the two Philips head screws fig 3 Then the internal side of the...

Page 17: ...ble the liquid should be thinned 4 Make sure that the temperature of the liquid being pumped does not exceed the max admissible value 5 Eliminate causes of dry running 4 Intermittent or irregular oper...

Page 18: ...be missing upon the return of the device we shall not be liable for them 11 How to order spare parts The fastest most simple and cheapest way of ordering spare parts is through the internet On our www...

Page 19: ...ls 1 Ablassseil 3 Netzanschlusskabel 5 Druckanschluss 2 sen zur Befestigung des Ablassseils 4 Ansaugfilter Ansaug ffnungen Functional parts Details 1 Lowering rope 3 Mains connection cable 5 Pressure...

Page 20: ...1 2014 T I P Technische Industrie Produkte GmbH Siemensstra e 17 D 74915 Waibstadt Germany service tip pumpen de www tip pumpen de...