Systems With Intelligence DVS500 Installation Manual Download Page 7

DVS500 Installation Guide - V1.0 

             www.SystemsWithIntelligence.com 

                                                                                   [email protected]   

© 2017 Systems With Intelligence.  All rights reserved.

7

IN

ST

AL

LA

TION

2  Dimensions 

* Note:

 

Units in Imperial (Metric).

3.72 in

(94.5 mm)

6.34 in

(161 mm)

2.94 in

(74.8 mm)

5.44 in

(138.2 mm)

Summary of Contents for DVS500

Page 1: ...hIntelligence com 2018 Systems With Intelligence All rights reserved DVS500 INSTALLATION GUIDE Version 1 0 SUBSTATION HARDENED DIGITAL VIDEO SERVER Note Please read this manual thoroughly before opera...

Page 2: ...of Systems With Intelligence Inc Disclaimer of Liability We have checked the contents of this manual against the hardware and software described However deviations from the description cannot be comp...

Page 3: ...he interference on his own expense CAUTION This product contains a laser system and is classified as a CLASS 1 LASER PRODUCT CAUTION Use of controls or adjustments or performance of procedures other t...

Page 4: ...m 5 1 2 Technical Specifications Overview 6 2 Dimensions 7 3 Power Supply 8 3 1 Power Supply Wiring 9 3 2 Dual Redundant Power Supply 9 4 Failsafe Relay 10 5 IP Camera Input 11 6 Serial Interface 12 6...

Page 5: ...x USB 2 0 Ports Digital Inputs 4 x Digital Inputs Digital Outputs 4 x Digital Outputs Mounting DIN rail mounts Substation Hardened IEC 61850 3 IEEE 1613 C37 90 400 C to 750 C Future option available s...

Page 6: ...es supported ONVIF IP Camera Support CPU Atom E3845 1 91GHz RAM 4GB DDR3L Power 30W Max Video Output 1 HDMI interface for computer monitor USB 2 USB 2 0 Ports Storage Up to 1TB LAN Interface Included...

Page 7: ...ystemsWithIntelligence com support SystemsWithIntelligence com 2017 Systems With Intelligence All rights reserved 7 INSTALLATION 2 Dimensions Note Units in Imperial Metric 3 72 in 94 5 mm 6 34 in 161...

Page 8: ...SUPPLY TYPE INPUT RANGE INTERNAL FUSE RATING POWER CONSUMPTION MIN MAX TYPICAL WORST CASE 24 48 VDC 20 VDC 60 VDC 5A T 15 W 20 W 25 W 30 W TERMINAL NUMBER DESCRIPTION USAGE Screw Chassis Ground Chassi...

Page 9: ...otes Equipment must be installed according to the applicable country wiring codes Connect the ground terminal on the power source to the chassis ground terminal on the DVS500 3 2 Dual Redundant Power...

Page 10: ...tput contact that can be used to communicate an alarm to another system e g remote terminal unit if the server stops working The failsafe relay is in open state normally open when the server is powere...

Page 11: ...IP Camera Input The DVS500 can be equipped with IP video inputs 4 port IP Camera Input cards are available with fiber optic SFP based LC connectors or RJ45 connectors All ports support 100Mbps inputs...

Page 12: ...4 relay switch output 30 VDC 1 Amp 50 VAC 5 Amps 6 1 Dry Contact Input Interface Connector Connector Part Number 1727570000 Manufacturer Weidm ller Description Conn Term Block 3 5mm pitch 8POS SN OR...

Page 13: ...Y1 O Common relay output 3 NO_RELAY2 O Normally open relay output 4 COM_RELAY2 O Common relay output 5 NO_RELAY3 O Normally open relay output 6 COM_RELAY3 O Common relay output 7 NO_RELAY4 O Normally...

Page 14: ...568 A wiring standard that characterizes minimum cabling performance specifications required for proper Gigabit Ethernet operation To ensure reliable error free data communications new and pre existi...

Page 15: ...the DVS500 has been designed to meet 8 1 Temperature Humidity 8 2 EMC EMI ESD 1 IEC 61850 3 Electric Utility Substations 2 IEEE 1613 Electric Utility Substations 3 IEC 61000 6 2 Industrial Generic 4...

Page 16: ...ne D C Power ports 2KV line to earth 1KV line to line IEC 61000 4 6 Induced Conducted RFI Signal Ports 10V 10V D C Power ports 10V Earth ground ports 10V IEC 61000 4 8 Magnetic Field Enclosure ports 1...

Page 17: ...x EMI IMMUNITYPE TESTS TEST DESCRIPTION TEST LEVELS IEEE C37 90 3 ESD Enclosure Contact 2KV 4KV 8KV Enclosure Air 4KV 8KV 15KV IEEE C37 90 2 Radiated RFI Enclosure ports 20 V m IEEE C37 90 1 Fast Tra...

Page 18: ...ries info SystemsWithIntelligence com Sales Inquiries sales SystemsWithIntelligence com Product Support support SystemsWithIntelligence com All specifications in this document are subject to change wi...

Reviews: