EMI TYPE TESTS
TEST
DESCRIPTION
TEST LEVELS
IEC 61000-4-2
ESD
Enclosure Contact
+/- 8KV
Enclosure Air
+/- 15KV
IEC 61000-4-3
Radiated
RFI
Enclosure ports
20 V/m
IEC 61000-4-4
Burst (Fast
Transient)
Signal ports
+/- 4KV @ 5KHz, 1 min
D.C. Power ports
+/- 4KV @ 5KHz, 1 min
Earth ground ports
+/- 4KV @ 5KHz, 1 min
IEC 61000-4-5
Surge
Signal ports
+/- 1KV line-to-line
D.C. Power ports
+/- 2KV line-to-earth
+/- 1KV line-to-line
IEC 61000-4-6
Induced
(Conducted
RFI)
Signal Ports 10V
10V
D.C. Power ports
10V
Earth ground ports
10V
IEC 61000-4-8
Magnetic
Field
Enclosure ports
100 A/m continuous, 1000 A/m for 1s
IEC 61000-4-29
Voltage Dips
& Interrupts
D.C. Power ports
18 VDC-30%
18 VDC-60%
18 VDC-100%
18 VDC+/-20%
60 VDC-30%
60 VDC-60%
60 VDC-100%
60 VDC+/-20%
IEC 61000-4-16
Main
Frequency
Voltage
Enclosure ports
20 V/m
IEC 61000-4-17
Ripple on
D.C. Power
Supply
D.C. Power ports
15% of rated voltage
IEC 60255-5
Dieletric
Strength
Signal ports
705 VDC, 1 min (Ethernet)
705 VDC, 1 min (Relay)
705 VDC, 1 min (Relay Contacts)
D.C. Power ports
705 VDC
IEC 60255-5
H.V. Impulse
D.C. Power ports
5KV