background image

PAGE         

10  

S

ection 2  

  T

erminating the wiring

Power supply

Power supply

From PIM

Not used in main zones. This connection 
is normally only used in sub zones or in 
expanded zones consisting of more than 1 
pair of speakers.

Note:

 Each coloured pair of CAT5/6 wires 

is doubled up.

Next (sub-zone) zone

This connection is used to feed audio and 
data to a sub-zone:

NEXT zone

Connects to system input

on next speaker

2.6 Confi guring the active 

speaker 

Mono operation

Should it be required to confi gure the 
active speaker for mono operation, move 
the switch shown in the diagram below 
from the factory default stereo setting to 
mono. In this mode, the speaker will mix 
both stereo channels into mono sound 
reproduction. If a passive speaker is 
connected, that too will operate in mono 
mode.

Disabling the LED display on IR 
equipped speakers

The facility exists on the IR equipped 
speaker to extinguish the status LED’s 
permanently if desired. This may be 
desirable if the customer does not wish to 
see the LEDs in a bedroom for example. 
Turning off the LEDs does not affect the 
speaker’s operation in any other way. 
Please refer to 

Deactivating the LED 

display on an IR equipped speaker

, page 

17, for details on how to do this. Do not 
disable LEDs until the system is fully 
tested.

2.7  Connecting the PLM2 

passive speaker 

In contrast to the active speaker, only one 
CAT5/6 cable should be trailing from this 
speaker hole.

Summary of Contents for Multi-room system

Page 1: ...MULTI ROOM SYSTEM Systemline Modular Installation Guide MULTI ROOM SYSTEM I n s t a l l a t i o n G u i d e...

Page 2: ...ded on the CD Rom accompanying the Systemline Modular Read all the instructions before connecting or operating the Systemline Modular Pay particular attention to the safety information Keep this manua...

Page 3: ...ple active speakers are used to distribute sound over a large area usually with synchronised volume control An expanded zone can also be configured with two or more areas of independent volume control...

Page 4: ...nt 13 Directly connected music source 13 Remotely connected music source 13 2 13 Connecting the PIM power input module for sub zones 14 2 14 Wiring for a single zone system no hub 14 3 Testing the sys...

Page 5: ...please ensure that you refer to the wiring schedule or equivalent document that details exactly how the home has been pre wired A wiring schematic and parts list should also be available We recommend...

Page 6: ...Guide and reprinted below Under stairs cupboard With new construction the wall socket point for the connection of the hi fi system would be located alongside the FM aerial socket in the lounge or fam...

Page 7: ...Remember also that for some small rooms such as ensuite bathrooms only a single mono speaker may have been provided for Clearance Drill a small diameter hole in the ceiling at the marked point and ch...

Page 8: ...iling The flange of the ceiling speaker bezel will cover any slight imperfections around the hole itself 2 4 Connecting the active right channel ceiling speaker Important Take the utmost care to ensur...

Page 9: ...local input and as a spare if another cable is found to be damaged Note No connections are normally made to the power supply input of the speaker when used as a main zone This is because power is norm...

Page 10: ...eo setting to mono In this mode the speaker will mix both stereo channels into mono sound reproduction If a passive speaker is connected that too will operate in mono mode Disabling the LED display on...

Page 11: ...in place 2 3 4 1 Continue to tighten the four mounting screws in rotation until the speaker is held firmly flush against the ceiling Do not over tighten as you may crack the mounting tabs or strip th...

Page 12: ...ypad to this mode Make sure that the keypad is operating normally put the zone into standby red LED ON Depress the O and VOL keys on the keypad simultaneously both together at exactly the same time Ho...

Page 13: ...red wiring systems The cradle for the power supply supplied should be mounted alongside the hub The PSM130 plugs into a suitable AC mains socket and should be mounted in its wall mounted cradle The DC...

Page 14: ...t inputs of the SIM module with the window emitters supplied plugged directly into the IR TX sockets on the IRM module and attached to the infra red receiving window of the hi fi system or music sourc...

Page 15: ...Using a patch cord assuming that a patch panel has been used connect the system input from the system room to the RJ 45 socket on the hub marked REMOTE AUDIO IN This connection is not required if the...

Page 16: ...doesn t happen try again The speaker system is now in setup mode Using the VOL and VOL keys on the remote adjust the volume to a level that you want the system to turn ON at This will be the turn ON...

Page 17: ...imultaneously both together at exactly the same time Hold briefly until you see the status LEDs flash The LEDs will flash to show you the new sequence which is Blue Green Blue Green Red Mode 2 Local e...

Page 18: ...e address unless you need to for independent sub zone operation The keypad must have its address set in the following way With the keypad connected to the speaker and the red standby LED ON depress th...

Page 19: ...rking this probably indicates a break or fault in the wiring between this zone and the audio distribution hub If no zones are working this probably indicates a fault in the wiring between the audio di...

Page 20: ...ing Some zones sound too loud when first switched on The start up volume is configurable for each active speaker Adjust the start up volume of the zone as described in Setting bass treble and minimum...

Page 21: ...the remote or O key on the keypad to toggle to the next input The green local LED will illuminate on the speaker and also on the keypad if fitted Note The volume will ramp down and the speaker will s...

Page 22: ...ON by pressing the O key on the keypad or remote Controlling of the audio source in the sub zone is done using either the original equipment remote or else a learning remote containing the source code...