background image

 

13 

REMOTE MANAGEMENT 

 
The C530xr Codec can be configured 
remotely by connecting a straight 9 Way D-
Type cable to the MGR IP port, and using the 
Standard Windows Terminal Program. To 
configure more than one unit at the same 
time, the user can connect another straight 
9 Way D-Type cable from the MGR OP port of 
the first unit, to the MGR IP port of the next 
unit, in a “Daisy Chain” manner. There are 
no limitations on the number of codecs 
which can be linked together for remote 
configuration purposes. 
 
On initial connection, the Standard Windows 
Terminal Program screen will be blank. The 
user should then press the Enter key to clear 
the command buffer.  
 
Type “poll” followed by the serial number :- 
 
poll 0108-001 < carriage return / enter > 

 

 
0108-001> 

 

 

 

 

 
A prompt of the actual serial number will 
appear on the screen. The unit is now ready 
to receive commands. 
 
Type “help” for a complete list of commands 
and options.  
 
0108-001 >help 
 
 
C530xr Network Commands, (c) Systembase 
Limited 
 

poll (8 digit serial number of unit to be 
selected) 
status (displays the codecs current status,  
/s option for short) 
 
set x21 (APTX:3K7 Stereo 64Kbps, 

APTX:7K5 Mono 64Kbps, 
APTX:7K5 Stereo 128Kbps, 
APTX:15K2 Mono 128Kbps, 

  

APTX:12K2 Stereo 192Kbps, 
APTX:22K5 Mono 192Kbps, 
APTX:15K2 Stereo 256Kbps, 
APTX:22K5 Stereo 384Kbps) 

 
set aux (Off,  

9600bps, 
4800bps, 
2400bps,   
9600bps(alt),  
4800bps(alt),  
2400bps(alt),  
Relay Mode) 

 
set source (Analog, AES3) 
 
set loopback (Off, On) 
 
 
The Status command will display the 
following information on the codec. 
 
0108-001>status 
 
SYSTEMBASE C530xr(c) 
 
APTX Status= SYNC 
Loopback= Off 
Aux Data= Off 
X21 Audio= APTX:22K5 Stereo 384Kbps 
Audio Source= Analog

 
 
 
 
 

Summary of Contents for C530xr

Page 1: ...SystemBase C C5 53 30 0x xr r User Manual D Di ig gi it ta al l A Au ud di io o C Co od de ec cs s...

Page 2: ...Options 9 Password 9 Loopback 9 Ethernet Options 9 Ethernet DHCP 9 IP Address 10 Ethernet Mask 10 Ethernet Gateway 10 Set Defaults 10 Ethernet Webserver 11 Email Alert Messages 12 Email Timing 12 REMO...

Page 3: ...e full duplex point to point audio transmission Key Features 32 Bit Floating Point DSP Analog Device SHARC Processor Internet Web Server for Remote Management and Diagnostics X 21 Connectivity 64Kbps...

Page 4: ...xt button Menu Select Edit button is used to select the configuration which is to be modified Menu Backspace button NO NO Cancel button is used to answer No or to abort the configuration change The NO...

Page 5: ...5 FRONT REAR PANELS...

Page 6: ...YES CONFIRM EDIT NO CANCEL EDIT LEFT TITLE SCREEN AUDIO SOURCE X 21 AUDIO AUDIO STATUS SYSTEM OPTIONS LOOP BACK PASSWORD SET DEFAULTS IP ADDRESS ETHERNET GATEWAY ETHERNET MASK ETHERNET OPTIONS SET PAS...

Page 7: ...to end synchronisation and not necessarily the configured mode AES Status The status screen displays information about the AES input data stream RX is the status of the AES audio receive signal Con C...

Page 8: ...for the following modes Off 9600bps 4800bps 2400bps 9600bps alt 4800bps alt 2400bps alt Relay Mode NOTE1 CTS output signal should be used for Flow Control when Auxiliary Data is enabled NOTE2 All mod...

Page 9: ...ailable when operating in Backup Master or Backup Slave modes Ethernet Options The C530xr can be remotely managed via the Ethernet Port The display will show Inactive Negotiation 100BASE TX full duple...

Page 10: ...e lost and there is no Undo option MENU Set Defaults MENU Set Defaults MENU Set Defaults MENU Set Defaults MENU Set Defaults MENU Set Defaults MENU Set Defaults MENU Set Defaults Confirm Yes No Confir...

Page 11: ...nce configured correctly connect the port labelled LAN to your router On your computer web browser type in the IP address of the codec http 192 168 0 2 A Windows Login screen will be displayed The def...

Page 12: ...SMTP mail server of your ISP for example mail myISP com If you leave this box blank no alerts or logs will be sent to you In the Subject box enter the text to be displayed in the email subject line I...

Page 13: ...001 carriage return enter 0108 001 A prompt of the actual serial number will appear on the screen The unit is now ready to receive commands Type help for a complete list of commands and options 0108...

Page 14: ...electrical characteristics of these connections is detailed below I P Connectors Balanced XLR Female O P Connectors Balanced XLR Male Compression Ratio 4 1 Fixed Coding Algorithm apt X100 Sub band ADP...

Page 15: ...r NOTE The CTS output signal should be used for Flow Control when Auxiliary Data is enabled Alarm Signal The C530xr provides a set of alarm relay contacts with a minimum of 0 5 second duration These r...

Page 16: ...declares that this product is in compliance with the Electromagnetic Compatibility Directive 2004 108 EC A Declaration of Conformity is available by contacting Systembase Limited This product is desi...

Page 17: ......

Page 18: ...time of publication The manufacturer reserves the right to change details without notice Systembase is a trademark of Systembase Limited apt X is a trademark of Audio Processing Technology Ltd All tr...

Reviews: