General information |

1

1

General information

1.1

Notice symbols

Danger

Direct hazard

Failure to comply with this warning will lead
directly to death or to serious injury.

Caution

Hazard with a low risk

Failure to comply with this warning may lead to
moderate injuries.

Warning

Potential hazard

Failure to comply with this warning may lead to
death or serious injury.

Important

Hazard with risk of damage to objects

Failure to comply with this warning will lead to
damage to objects.

Note:

Useful information and instructions

1.1.1

Instruction symbols

Instruction

Instruction with fixed sequence

Carry out this action

1. Carry out this action

3. (if applicable, further actions)

(if applicable, further actions)

2. Carry out this action

2

Important safety information

Planners, plant builders and operators are responsible for the proper assembly and intended use.

Read the operating instructions completely and carefully.

Keep the operating instructions and other valid documents, such as the circuit diagram or motor instructions, with
the fan. They must always be available at the place of use.

Observe and respect local conditions, regulations and laws.

Only use the fan in a flawless condition.

Provide generally prescribed electrical and mechanical protective devices.

During installation, electrical connection, commissioning, troubleshooting, and maintenance, secure the location and
premises against unauthorised access.

Do not circumvent any safety components or put them out of action.

Keep all the warning signs on the fan complete and in a legible condition.

The device is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they have been given supervision or instruction.

Do not allow children to play with the device.

2.1

Personnel

The fan may only be used by qualified, instructed and trained personnel. The persons must know the relevant safety di-
rectives in order to recognise and to avoid risks. The individual activities and qualifications can be found in Table 1

Qual-

ifications

, page 1.

Table 1 Qualifications

Activities

Qualifications

Storage, operation, transport, cleaning, disposal

Trained personnel (see following note)

Electrical connection, commissioning, electrical
disconnection

Electrical expert or matching qualification

| 007

Summary of Contents for Multibox MUB Series

Page 1: ...Document in original language 007 Multibox MUB MUB T MUB T S MUB CAV VAV MUB F Installation and Operating Instructions GB...

Page 2: ...emair AB All rights reserved E OE Systemair AB reserves the rights to alter their products without notice This also applies to products already ordered as long as it does not affect the previously agr...

Page 3: ...0 8 3 Installation variations 11 8 4 Changing the discharge direction 12 8 5 Weather protection roof WSD 13 8 6 Weather protection grille WSG 14 8 7 Assembly Disassembly impeller Internal rotor motor...

Page 4: ......

Page 5: ...lable at the place of use Observe and respect local conditions regulations and laws Only use the fan in a flawless condition Provide generally prescribed electrical and mechanical protective devices D...

Page 6: ...arranty For the assertion of warranty claims the products must be correctly connected and operated and used in accordance with the data sheets Further prerequisites are a completed maintenance plan wi...

Page 7: ...nsport please make sure that no water can penetrate into the motor or other sensitive parts We recommend transporting the fan to the installation site in the original packaging Caution If transported...

Page 8: ...or error message 5 2 MUB equipped with an AC motor For information on speed regulation options see 6 Name plate and type key page 8 5 3 Description MUB Table 2 Dimensions MUB mm A B C D A D C B MUB 02...

Page 9: ...sibility for a constant airflow factory setting or a constant pressure ventilation or just to display data Constant air volume function CAV If the air volume factory setting is to be kept constant the...

Page 10: ...factor MUB CAV VAV 025 315EC 100 042 400EC 172 042 450EC K 235 062 560EC 418 100 630EC 456 025 355EC 143 042 450EC 238 042 500EC 266 062 630EC 500 100 710EC 550 5 6 Description MUB F The fan is equipp...

Page 11: ...a max air humidity of 80 MUB and MUB CAV VAV The fan is suitable for conveying clean air with a density of 1 3 kg m3 and a max air humidity of 95 MUB T and MUB T S The fan is suitable for conveying co...

Page 12: ...Electronically commutated 1 phased or 3 phased E2 2 poled controllable by frequency converter 1 phased E4 4 poled controllable by frequency converter 1 phased DV 4 poled voltage controllable 3 phased...

Page 13: ...G Weather protection grille 3 UGS Transition connections square to round 4 Tune AHU Damper 5 WSD Weather protection roof 6 MUB Multibox 8 6 Weather protection grille WSG page 14 8 5 Weather protection...

Page 14: ...es according to DIN EN ISO13857 and DIN 24167 1 Use vibration dampers to prevent vibration transmissions For example article 37324 in our accessory range Prevent the possibility of foreign bodies bein...

Page 15: ...ht ducts page 11 Rectangular duct system D Hydraulic diameter Round duct system D Nominal diameter D min 2 5x D min 2 5x D Fig 1 Straight ducts 8 3 Installation variations MUB T MUB T S Important Dama...

Page 16: ...direction 90 upwards factory assembly 2 MUB T with airflow direction 90 sideways 3 Change of airflow direction As a default the Multiboxes have been designed for an inline airflow direction The airfl...

Page 17: ...ure Only install outdoors with the weather protection roof from our accessory range see chapter Accessories Install the weather protection roof as described below 1 2 3 4 5 6 1 Weather protection roof...

Page 18: ...the correct WSG for your Multibox from the Systemair online catalogue Standard version B B 1 2 3 4 5 1 Catch nut 2 Cap nut 3 Double facets ring 4 Double facets ring 5 Distance bolt Turned version 1 Se...

Page 19: ...without forceful impacts Do not separate the impeller and the hub They were balanced as one unit by Systemair Note The hub can be heated for easier assembly and disassembly for example with a hot air...

Page 20: ...2 1 The set screw must push on the wedge of the shaft Use screw locking 5 Steel hub 6 Steel hub Tighten the screws slightly Tighten the two screws evenly with the tightening torque according to table...

Page 21: ...of at least 3 mm at each pole 9 3 Connection Check if the data on the nameplate matches the connection data Complete the electrical connection according to the circuit diagram Lay the connection cabl...

Page 22: ...wn Motor lines and temperature monitor lines should be laid separately on principle Without thermal protection Use a motor protection switch 9 8 Variable speed fans Warning Resonant frequencies may re...

Page 23: ...10 3 Tests Before switching the fan on check for externally visible damage and ensure that the protective equipment functions properly AC motor EC motor 1 Switch the fan on 2 Checks Direction of rotat...

Page 24: ...The impeller must be at a standstill 12 2 Troubleshooting Table 13 Troubleshooting Problem Possible causes Remedy Fan does not run smoothly Impeller imbalance Rebalancing by a specialist company if po...

Page 25: ...ntrol units if used such as frequency converter or transformer are set incorrectly Correct the settings of the control units Mechanical blockage Remove the blockage Motor does not rotate Faulty supply...

Page 26: ...imbalance X X Check the condensate drain is working correctly X X Clean the fan ventilation system see 13 Cleaning page 23 X X Check the screwed connections for damages defects and check that they are...

Page 27: ...d objects Do not use a high pressure cleaner steam jet cleaner under any circumstances Do not bend the fan blades when cleaning When cleaning the impeller pay attention to balance weights that have be...

Page 28: ...nation Thermo fans Type designation AxZent KBT KBR MUB K MUB T MUB T S MUB T EC MUB T S EC DVN DVN EC DVNI DVNI Since year of manufacture 2016 The manufacturer declares that the above mentioned produc...

Page 29: ...ectly to mains 0 10 V signal EC motor via contactor control Transformer Frequency converter Sinus filter Shielded cables Motor protection Yes No Motor protection switch or motor protection relay PTC r...

Page 30: ...essure between suction side and discharge of the fan If an air flow measurement is not possible this value can be calculated using the following formula X Duct cross section m Flow speed m s Grille me...

Page 31: ...007...

Page 32: ...Multibox Installation and Operating Instructions en_GB 2018 10 08 007 Systemair GmbH Seeh fer Str 45 97944 Boxberg Germany Tel 49 0 7930 9272 0 Fax 49 0 7930 9273 92 info systemair de www systemair de...

Reviews: