SystemAir fantech FG 10 Installation And Operation Manual Download Page 5

5

 

Exhaust system 

Ceiling exhaust system 

Horizontal installation 

Exhaust system

INSTALLATIONS

INSTALLATION DIAGRAM FOR MODEL FG DUCT FANS

Illustration 1

Fan bracket should be installed, then fan mounted directly to bracket using sheet metal screws.

Models 

• 6XL 

• 10/10XL

• 8/8XL 

Models 

• 4/4XL  • 6
• 5/5XL

Models

 

• 12XL

1. When installing, keep the number of elbows and bends to a minimum.  If necessary, long radius elbows or bends are    

recommended.

2. Duct sealant, caulk, or tape should be applied to all seams, including around the opening in the wall or ceiling on the interior and 

around exterior building penetrations, to prevent air leakage and maximize air performance.

3. Flex, spiral, or snap lock ducting may be used.  If using rigid duct, Fantech FC clamps are recommended to connect duct work to  

the fan (see illustration 2). FC clamps make an air tight seal at the connection points and reduce vibrations transmitted 
throughout the duct system. If screws are 

used, do not locate them in the entrance duct less than half an inch from the housing 

(see illustration 3).

4. To minimize static pressure losses and promote adequate airflow, minimize duct run lengths where possible.  If using flex duct, 

keep duct runs straight and taut.

5. If installing in an unconditioned space, covering the fan with insulation is recommended to prevent condensation from forming.
6.  For general ventilation applications, at least 8 ft of insulated flexible duct shall be installed between the exhaust or supply grille(s) 

and the fan.

The ducting from this fan to the outside of the building has a strong effect on the air flow, noise and energy use of the fan.  Use the 
shortest, straightest duct routing possible for best performance, and avoid installing the fan with smaller ducts than recommended.  
Insulation around the ducts can reduce energy loss and inhibit mold growth.  Fans installed with existing ducts may not achieve their 
rated air flow.

Use long screws (bracket-wall) to mount the bracket and short screws (bracket-fan) for fan.

Summary of Contents for fantech FG 10

Page 1: ...de l ACMA et r pondent aux exigences du programme de certification des caract ristiques Systemair Inc certifica que los modelos que aparecen en este documento est n autorizados para llevar el sello de...

Page 2: ...rte tornillos a trav s de la abrazadera a las bridas de entrada y salida PRECAUCION Utilice tornillos de 1 2 pulgada para hojalata para fijar el conducto a la entrada y sali da Es esencial que los tor...

Page 3: ...u fabricant pour les appareils de chauffage et respectez les normes de s curit comme celles tablies par la National Fire Protection Association NFPA et la American Society for Heating Refrigeration an...

Page 4: ...7 1 1 FG 8 8 13 1 4 6 1 1 FG 8XL 8 13 1 4 6 1 1 8 1 FG 10 10 13 1 4 4 3 4 1 1 8 1 FG 10XL 10 13 1 4 4 13 16 1 1 4 1 FG 12XL 12 16 6 11 16 1 1 2 1 Parts in the box Pi ces dans la bo te Partes en la ca...

Page 5: ...nsmitted throughout the duct system If screws are used do not locate them in the entrance duct less than half an inch from the housing see illustration 3 4 To minimize static pressure losses and promo...

Page 6: ...AINTENANCE 1 Since fan bearings are sealed and have been provided with an internal lubricating material no lubrication is necessary 2 Once a year remove any airborne particles in the impeller No other...

Page 7: ...ibrations transmises trav ers le r seau de conduits Si des vis sont utilis es dans l entr e du conduit ne les placez pas moins d un demi pouce du bo tier voir illustratation 3 4 Pour minimiser les per...

Page 8: ...CTIONS POUR 120 et 230 V MOTEURS Contr le de vitesse du moteur Condensateur Moteur Noir L Blanc N Vert GRD Brun Noir Bleu Avec contr le de vitesse Condensateur Moteur Brun Noir Bleu Sans contr le de v...

Page 9: ...s coloque en el cuello de entrada a menos de media pulgada del ventilador se pueden bloquear las aspas vea la ilustraci n 3 4 Para minimizar las p rdidas de presi n est tica y promover de una ventilac...

Page 10: ...ara que quede libre de part culas acumuladas INSTRUCCIONES PARA 120V y 230V MOTORES Control de velocidad del motor Capacitor Motor Negro Blanco Verde Marr n Negro Azul Oscuro Con control de velocidad...

Page 11: ...tte ou pour une o une grille d vacuation raccord e au ventilateur est situ e audessus ou pr s du dessus de la cuisini re comme d montr e suivez les directives suivantes AVERTISSEMENTS AFIN D VITER LES...

Page 12: ...quemar C No use agua ni trapos o toallas mojadas Puede causar una explosi n violenta de vapor D Use un extintor solamente si 1 Usted sabe que tiene un extintor Clase ABC y sabe como funciona 2 El fue...

Page 13: ...13 NOTES REMARQUES NOTAS...

Page 14: ...14 NOTES REMARQUES NOTAS...

Page 15: ...15 NOTES REMARQUES NOTAS...

Page 16: ...des ventilateurs et des ventilateurs distance qualifi s ENERGY STAR chaque ventilateurs doit tre install en utilisant des techniques d att nuation du son appropri es pour l installation Pour les appl...

Reviews: