SystemAir fantech FG 10 Installation And Operation Manual Download Page 16

Fantech reserves the right to make technical changes.
For updated documentation please refer to www.fantech.net

Fantech®

Fantech se réserve le  droit de faire des changements 
techniques. Pour de la documentation à jour, s'il vous plaît se 
référer au www.fantech.net

Fantech se reserva el derecho de hacer modificaciones 
técnicas en cualquier momento. Para obtener la documen-
tación actualizada, por favor consulte www.fantech.net

To ensure quiet operation of ENERGY STAR

®

 qualified inline and remote fans, each fan shall be installed using sounds attenuation techniques appropriate  for the installation. 

For bathroom and general ventilation applications, at least 8 feet of insulated duct shall  be installed between the exhaust or supply grilles(s) and the fan. For kitchen range hood 
remote ventilation applications, where metal duct is generally required by code, a metal sound attenuator shall be installed between the range hood and the fan.

Pour assurer un fonctionnement silencieux des ventilateurs et des ventilateurs à distance qualifiés ENERGY STAR

®

, chaque ventilateurs doit être installé en utilisant des techniques 

d'atténuation du son appropriées pour l'installation. Pour les applications de salles de bain et les applications de ventilation générales, au moins 8 pieds de conduits flexible isolé 
doivent être installées entre les grilles d'évacuation et d'approvisionnement du ventilateur. Pour les applications de hotte de cuisinière à distance, où un conduit en métal est 
généralement requis par le code du bâtiment, un atténuateur acoustique en métal doit être installé entre la hotte et le ventilateur. 

Para asegurar una operación silenciosa de los ventiladores en línea certificados ENERGY STAR

®

, cada ventilador debe instalarse utilizando técnicas de atenuación de sonido 

apropiadas para cada caso. Para baños y aplicaciones comunes de ventilación se recomienda instalar por lo menos 8’ de ducto flexible con aislamiento entre la rejilla de expulsión 
y/o inyección y el ventilador. Para campanas de cocina con un ventilador de extracción remoto, done se usa por código ducto rígido, se recomienda instalar un atenuador de sonido 
entre la campana y el ventilador.

Summary of Contents for fantech FG 10

Page 1: ...de l ACMA et r pondent aux exigences du programme de certification des caract ristiques Systemair Inc certifica que los modelos que aparecen en este documento est n autorizados para llevar el sello de...

Page 2: ...rte tornillos a trav s de la abrazadera a las bridas de entrada y salida PRECAUCION Utilice tornillos de 1 2 pulgada para hojalata para fijar el conducto a la entrada y sali da Es esencial que los tor...

Page 3: ...u fabricant pour les appareils de chauffage et respectez les normes de s curit comme celles tablies par la National Fire Protection Association NFPA et la American Society for Heating Refrigeration an...

Page 4: ...7 1 1 FG 8 8 13 1 4 6 1 1 FG 8XL 8 13 1 4 6 1 1 8 1 FG 10 10 13 1 4 4 3 4 1 1 8 1 FG 10XL 10 13 1 4 4 13 16 1 1 4 1 FG 12XL 12 16 6 11 16 1 1 2 1 Parts in the box Pi ces dans la bo te Partes en la ca...

Page 5: ...nsmitted throughout the duct system If screws are used do not locate them in the entrance duct less than half an inch from the housing see illustration 3 4 To minimize static pressure losses and promo...

Page 6: ...AINTENANCE 1 Since fan bearings are sealed and have been provided with an internal lubricating material no lubrication is necessary 2 Once a year remove any airborne particles in the impeller No other...

Page 7: ...ibrations transmises trav ers le r seau de conduits Si des vis sont utilis es dans l entr e du conduit ne les placez pas moins d un demi pouce du bo tier voir illustratation 3 4 Pour minimiser les per...

Page 8: ...CTIONS POUR 120 et 230 V MOTEURS Contr le de vitesse du moteur Condensateur Moteur Noir L Blanc N Vert GRD Brun Noir Bleu Avec contr le de vitesse Condensateur Moteur Brun Noir Bleu Sans contr le de v...

Page 9: ...s coloque en el cuello de entrada a menos de media pulgada del ventilador se pueden bloquear las aspas vea la ilustraci n 3 4 Para minimizar las p rdidas de presi n est tica y promover de una ventilac...

Page 10: ...ara que quede libre de part culas acumuladas INSTRUCCIONES PARA 120V y 230V MOTORES Control de velocidad del motor Capacitor Motor Negro Blanco Verde Marr n Negro Azul Oscuro Con control de velocidad...

Page 11: ...tte ou pour une o une grille d vacuation raccord e au ventilateur est situ e audessus ou pr s du dessus de la cuisini re comme d montr e suivez les directives suivantes AVERTISSEMENTS AFIN D VITER LES...

Page 12: ...quemar C No use agua ni trapos o toallas mojadas Puede causar una explosi n violenta de vapor D Use un extintor solamente si 1 Usted sabe que tiene un extintor Clase ABC y sabe como funciona 2 El fue...

Page 13: ...13 NOTES REMARQUES NOTAS...

Page 14: ...14 NOTES REMARQUES NOTAS...

Page 15: ...15 NOTES REMARQUES NOTAS...

Page 16: ...des ventilateurs et des ventilateurs distance qualifi s ENERGY STAR chaque ventilateurs doit tre install en utilisant des techniques d att nuation du son appropri es pour l installation Pour les appl...

Reviews: