SystemAir Fantech 5BDD 10 Installation And Operational Manual Download Page 14

14

Shell Belt Drive Fan Components List (cont.)

Model

Shell

Roof curb

HP

1 Phase

3 Phase

Drive Pack

Motor

Drive Pack

Motor

Art. #

Weight,
lbs

Max 
Opening 
Dimensions

Model

Art. #

Weight,
lbs

Art. #

DP ID

Art. #

Motor ID 

Art. #

DP ID

Item #

Motor 
ID

5BDD10

49810  90

19” x 19”

5ACC17FS /FT /VC 47206 / 47207 / 47208

24 / 29 / 38   1/4 

48992 

DP-10"-BB

49907

MOT BB

5BDD12

49811   100

22” x 22”

5ACC20FS /FT /VC 47212 / 47213 / 47214

28 / 33 / 38   1/4 

48993

DP-12"-BB

49907 

MOT BB

  1/3 

48994 

DP-12"-CB

49909

MOT CB

5BDD13

49812  110

22” x 22”

5ACC20FS /FT /VC 47212 / 47213 / 47214

28 / 33 / 38   1/4 

48995 

DP-13"-BB

49907 

MOT BB

  1/3 

48996 

DP-13"-CB

49909

MOT CB

  1/2 

48997

DP-13"-DB

49910 

MOT DB

49000

DP-13"-DX

49911

MOT DX

5BDD15

49813  120

26” x 26”

5ACC24FS /FT /VC 47217 / 47941 / 47219

33 / 38 / 47   1/4 

49001 

DP-15"-BB

49907

MOT BB

  1/3 

49002

DP-15"-CB

49909

MOT CB

  1/2 

49003

DP-15"-DB

49910

MOT DB

49004

DP-15"-DX

49911 

MOT DX

  3/4 

49005 

DP-15"-EB/EX

49912 

MOT EB

49005 

DP-15"-EB/EX

49913

MOT EX

1

49007 

DP-15"-FB/FX

49914 

MOT FB

49007 

DP-15"-FB/FX

49915 

MOT FX

5BDD16

49814  130

26” x 26”

5ACC24FS /FT /VC 47217 / 47941 / 47219

33 / 38 / 47 1/3

49010   DP-16"-CB

49909

MOT CB

1/2

49011   DP-16"-DB

49910

MOT DB

49012

DP-16"-DX

49911

MOT DX

3/4

49013   DP-16"-EB/EX

49912 

MOT EB

49013   DP-16"-EB/EX

49913    MOT EX

1

49015 

DP-16"-FB/FX

49914

MOT FB

49015 

DP-16"-FB/FX

49915

MOT FX

5BDD18

49815

164

30” x 30”

5ACC28FS /FT /VC 47221 / 47222 / 47223

40 / 48 / 54 1/3

49017 

DP-18"-CB

49909

MOT CB

1/2

49018 

DP-18"-DB

49910 

MOT DB

49019

DP-18"-DX

49911 

MOT DX

3/4

49020 

DP-18"-EB/EX

49912

MOT EB

49020 

DP-18"-EB/EX

49913 

MOT EX

1

49022 

DP-18"-FB/FX

49914 

MOT FB

49022 

DP-18"-FB/FX

49915

MOT FX

1-1/2

49024 

DP-18"-GB

49916 

MOT GB

49024 

DP-18"-GB

49917

MOT GX

2

49026

DP-18"-HX

49918

MOT HX

5BDD20

49816

185

30” x 30”

5ACC28FS /FT /VC 47221 / 47222 / 47223

40 / 48 / 54 1/3

49027 

DP-20"-CB

49909

MOT CB

1/2

49028 

DP-20"-DB

49910

MOT DB

49029

DP-20"-DX

49911 

MOT DX

3/4

49031 

DP-20"-EB/EX

49912

MOT EB

49031 

DP-20"-EB/EX

49913 

MOT EX

1

49032

DP-20"-FB/FX

49914

MOT FB

49032

DP-20"-FB/FX

49915 

MOT FX

1-1/2

49036

DP-20"-GB/GX

49916 

MOT GB

49036

DP-20"-GB/GX

49917 

MOT GX

2

49038

DP-20"-HX

49918

MOT HX

5BDD24

49817

212

34” x 34”

5ACC32FS /FT /VC 47226 / 47227 / 47228

46 / 53 / 52 1/3

49039

DP-24"-CB

49909

MOT CB

1/2

49040 

DP-24"-DB

49910

MOT DB

49041

DP-24"-DX

49911

MOT DX

3/4

49042 

DP-24"-EB/EX

49912 

MOT EB

49042 

DP-24"-EB/EX

49913 

MOT EX

1

49044 

DP-24"-FB/FX

49914

MOT FB

49044 

DP-24"-FB/FX

49915

MOT FX

1-1/2

49046

DP-24"-GB/GX

49916 

MOT GB

49046

DP-24"-GB/GX

49917   MOT GX

2

49051

DP-24"-HX

49918 

MOT HX

5BDD30

49818  310

42” x 42”

5ACC40FS /FT /VC 47233 / 47901 / 47234

57 / 68 / 63 1/2

49466 

DP-30"-DB

49910

MOT DB

49052 

DP-30"-DX

49911

MOT DX

3/4

49053

DP-30"-EB/EX

49912 

MOT EB

49053 

DP-30"-EB/EX

49913   MOT EX

1

49055

DP-30"-FB/FX

49914

MOT FB

49055

DP-30"-FB/FX

49915 

MOT FX

1-1/2

49057

DP-30"-GB/GX

49916 

MOT GB

49057 

DP-30"-GB/GX

49917   MOT GX

2

49060 

DP-30"-HX

49918

MOT HX

3

49061 

DP-30"-JX

49919

MOT JX

5

49062 

DP-30"-KX

49920 

MOT KX

5BDU36

49809 

385

46” x 46”

5ACC44FS /FT /VC 47237 / 47238 / 47665

68 / 73 / 92  3/4

49063 

DP-36"-EB/EX

49912

MOT EB

49063 

DP-36"-EB/EX

49913

MOT EX

1

49065 

DP-36"-FB/FX

49914 

MOT FB

49065 

DP-36"-FB/FX

49915 

MOT FX

1-1/2

49067 

DP-36"GB/GX

49916 

MOT GB

49067   DP-36"GB/GX

49917 

MOT GX

2

49069   DP-36"-HX

49918

MOT HX

3

49070   DP-36"-JX

49919 

MOT JX

5

49072

DP-36"-KX

49920

MOT KX

Summary of Contents for Fantech 5BDD 10

Page 1: ...the ventila tors shown herein are licensed to bear the AMCA Seal The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and com...

Page 2: ...ome in contact with sharp objects oil grease hot surfaces or chemicals 6 Never open access door to a duct with the ventilator running 7 Do not operate direct drive fans with speed controller less than...

Page 3: ...age with the nameplate voltage and wiring diagrams 3 The main power wiring should be sized for the amperage shown on the nameplate Size wires in accordance with the ampacity tables in Article 310 of t...

Page 4: ...urb for the 5FSU10 fan 3 Use 5ACC32FS 8 roof curb for the 5FSU12 fan Alternate methods by others 4 Remove the wood nailer from the top of the roof curb 5 Install a neoprene gasket on the roof curb whe...

Page 5: ...nuous duty With proper installation and maintenance years of operating efficiency can be added to the lifespan of the V belt drive The condition of V belts and the amount of belt tension should be che...

Page 6: ...are apparent the belt should be replaced Check the sheaves also for chipping dents or rough surfaces which could damage the belt 7 The correct belt tension is important Too tight of a belt will result...

Page 7: ...ng in wrong direction 2 Wheel rubbing on inlet venturi 3 Fan speed higher than design 4 Worn fan bearings Excessive noise 1 Wheel or sheaves loose 2 Bearing or drive misalignment 3 Accumulation of mat...

Page 8: ...2 5BDD 30 30 1 3 16 42 51 7 16 37 1 2 8 13 32 1 1 2 310 37 1 2 SQ 40 1 2 5BDD 36 36 1 2 1 3 16 46 60 41 5 8 10 1 2 1 1 2 380 43 1 2 SQ 44 1 2 Dimensional information is in inches Belt Drive Downblast...

Page 9: ...SQ 32 1 2 5BDU 30 30 1 3 16 42 49 1 2 41 1 8 27 5 8 1 1 2 305 37 1 2 SQ 40 1 2 5BDU 36 36 1 2 1 3 16 46 58 1 16 45 1 8 31 1 4 1 1 2 385 43 1 2 SQ 44 1 2 Dimensional information is in inches Belt Drive...

Page 10: ...1 P 2 T 8 T 3 T 2 T 5 T 4 LINE LINE LINE LINE TAPE TAPE TAPE LOW VOLT CONN HIGH VOLT CONN CCW ROTATION SWITCH END TO REVERSE ROTATION INTER CHANGE LEADS T5 AND T8 5BDU 5BDD 13DX 15DX 16DX 16EX 18DX 1...

Page 11: ...OR IS CCW ROTATION LEAD END TO REVERSE INTERCHANGE RED AND BLACK LEADS UNGROUNDED SIDE OF LINE CONNECTIONS LINE BLU LINE BLU BRN RED ORG INS WHT RED ORG INS WHT YEL BLK LINE BRN INS YEL BLK LINE 5BDU...

Page 12: ...N PLASTIC POCKET TO REVERSE ROTATION INTERCHANGE RED BLK LEADS Motor Location Diagram Incorrect motor location Correct motor location 1 Mount motor in matching slot pattern provided 2 Install belt wit...

Page 13: ...8 FB FX 49914 MOT FB 49022 DP 18 FB FX 49915 MOT FX 1 1 2 49024 DP 18 GB 49916 MOT GB 49024 DP 18 GB 49917 MOT GX 2 49026 DP 18 HX 49918 MOT HX 5BDU20 49806 173 30 x 30 5ACC28FS FT VC 47221 47222 4722...

Page 14: ...P 18 FB FX 49914 MOT FB 49022 DP 18 FB FX 49915 MOT FX 1 1 2 49024 DP 18 GB 49916 MOT GB 49024 DP 18 GB 49917 MOT GX 2 49026 DP 18 HX 49918 MOT HX 5BDD20 49816 185 30 x 30 5ACC28FS FT VC 47221 47222 4...

Page 15: ...exa KS 66215 Included in the claim should be Order Number Model Numbers Serial Numbers and a detailed description of the issues Purchaser assumes all other responsibility for any loss damage or injury...

Page 16: ...Fantech reserves the right to make technical changes For updated documentation please refer to www fantech net Fantech...

Reviews: