Innovair™ 200 Series Specifications 

Operating Temperature Range

32° to 131°F (0° to 55°C) 

Operating Humidity Range

10% to 93% relative humidity

(non-condensing)

Duct Air Velocity

500 - 4000 ft./min. (2.54 - 20.32 m/s)

Length

14-3/8” (37 cm)

Width 

5-1/2” (14 cm)

Depth 

2-3/4” (7 cm)

Ordering Information

Par t No.

Description

DH200P

Innovair™ intelligent photoelectric non-relay duct 
smoke detector

DH200RP

Innovair™ intelligent photoelectric with relay duct

smoke detector

ST-1.5

Metal sampling tube duct widths 1’–2’

ST-3

Metal sampling tube duct widths 2’–4’

ST-5

Metal sampling tube duct widths 4’–8’

ST-10

Metal sampling tube duct widths 8’–12’

A5053

Replacement photoelectric sensor board

A5060

Replacement power board for DH200RP (w/relay)

A5067

Replacement power board for DH200P (w/o relay)

Accessories

Description

RTS451

Remote test station (see below)

RTS451KEY

Remote test station w/key (see below)

RA400Z

Remote LED (see below)

PA400

Mini-Aler t™ Sounder (see below)

F36-09-11

Replacement filters

M02-04-00

Test magnet

P48-21-00

End cap for metal sampling tube

P48-55-00

End cap for plastic sampling tube

S08-39-01

Replacement photo insect screen

T80-71-00

Replacement plastic sampling tube 

RTS451

Remote Test Station
(UL S2522)

RTS451KEY

Remote Test Station with
Key (UL S2522)

RA400Z

Remote
Annunciator
(UL S2522)

PA400

Mini-Aler t™ Sounder
(UL S3593)
Device can not be wired
directly to DH200P
(non-relay).

ALARM

RESET

ALARM

ON

RESET

TEST

System Sensor Headquarters

3825 Ohio Avenue
St. Charles, IL 60174
Ph: 800/SENSOR2
Fx: 630/377-6495 
Documents-on-Demand
800/736-7672 x3
www.systemsensor.com

System Sensor Canada

Ph: 905.812.0767 
Fx: 905.812.0771

System Sensor Europe

Ph: 44.1403.276500 
Fx: 44.1403.276501

System Sensor in China

Ph: 86.29.524.6253 
Fx: 86.29.524.6259

System Sensor in Singapore

Ph: 65.273.2230 
Fx: 65.273.2610

System Sensor – Far East

Ph: 85.22.191.9003 
Fx: 85.22.736.6580

System Sensor – Australia

Ph: 613.54.281.142 
Fx: 613.54.281.172

System Sensor – India

Ph: 91.11.558.2119
Fx: 91.11.567.6815

System Sensor Sales and Service

Summary of Contents for Innovair 200 Series

Page 1: ... the UL recognized power and sensor boards WARNING Duct smoke detectors have specific limitations DUCT SMOKE DETECTORS ARE NOT a substitute for an open area smoke detector NOT a substitute for early warning detection and NOT a replacement for a building s regular fire detection system Refer to NFPA 72 and 90A for additional duct smoke detector application information Air velocity rating from 500 t...

Page 2: ...uct by passing through the duct housing Terminal connections shall be of the strip and clamp method suitable for 12 18 AWG wiring Architect Engineer Specifications Voltage Range 15 to 32 VDC Standby Current 300µA 24 VDC one communication every 5 seconds with LED blink enabled Wiring diagram for DH200P Duct Smoke Detector with optional RA400Z Must break tab on back of RA400Z when used with DH200P W...

Page 3: ...ns J1 shunt must be removed for power supervision DH200RP Specifications Alarm auxiliary contacts DPDT 10 A 30 VDC 10 A 277 VAC 0 75 power factor 240 VA 249 VAC 0 4 power factor 1 8 HP 120 VAC 1 4 HP 240 VAC Supervisory contact SPST 2 0 A 30 VDC resistive Minimum switching current for auxiliaty contact must be 500 mA DC minimum 24 VDC Contact Ratings Accessory Current Loads at 24 VDC COM COM COM C...

Page 4: ...1KEY Remote test station w key see below RA400Z Remote LED see below PA400 Mini Alert Sounder see below F36 09 11 Replacement filters M02 04 00 Test magnet P48 21 00 End cap for metal sampling tube P48 55 00 End cap for plastic sampling tube S08 39 01 Replacement photo insect screen T80 71 00 Replacement plastic sampling tube RTS451 Remote Test Station UL S2522 RTS451KEY Remote Test Station with K...

Reviews: