background image

D200-102-00

6

I56-3888-203  

Pittway Tecnologica S.r.l. Via Caboto 19/3, 34147 TRIESTE, Italy

Figure 11:  Front Panel Display

11b:  FL2012EI 1 Channel Detector (2 Sensors)

11a:  FL2011EI 1 Channel Detector (1 Sensor)

FRONT PANEL

The front panel will be different depending on which of the 3 FL20 

models is being installed, and each is shown below.
The following information is displayed:

•   Detector Status: Normal, Alarm, Fault or Isolate

•   Alarm  Level;  Alarm,  Pre-Alarm  (only  available  with  panels 

using Advanced Protocol)

•   Particulate  Levels;  1-9  (only  available  with  panels  using 

Advanced Protocol)

•   Flow Level

•   Test, Reset and Disable Buttons

11c:  FL2022EI 2 Channel Detector

ALARM

PREALARM

MODULE

LEVEL

SMOKE

FAULT

FAULT

POWER

INPUT

SENSOR

ASPIRA

T

OR

E

L

B

A

SI

D

/
M

E

T

S

Y

S

TEMPER

A

TURE

SOUNDER

FIL

TER

LOW

FLOW

HIGH

FLOW

2

10

3

1

4

5

6

7

8

9

MODULE

LEVEL

SMOKE

FAULT

FAULT

POWER

ALARM

PREALARM

INPUT

SENSOR

ASPIRA

T

OR

TEMPER

A

TURE

SOUNDER

FIL

TER

LOW

FLOW

HIGH

FLOW

E

L

B

A

SI

D

/
M

E

T

S

Y

S

2

10

3

1

4

5

6

7

8

9

MODULE 1

LEVEL 1

SMOKE

FAULT

FAULT

POWER

LEVEL 2

SMOKE

MODULE 2

ALARM

PREALARM

INPUT

SENSOR

ASPIRA

T

OR

E

L

B

A

SI

D

/
M

E

S

Y

TEMPERA

TURE

SOUNDER

FIL

TER

LOW

FLOW

HIGH

FLOW

S

T

2

10

3

1

4

5

6

7

8

9

2

10

3

1

4

5

6

7

8

9

Summary of Contents for FL2011EI

Page 1: ...ator Characteristics Maximum rated switching current under short circuit Is max 0 9A 29V Maximum leakage current IL max with the switch open isolated state 15mA Maximum series impedance with the switc...

Page 2: ...xed in place This allows the installer to choose the language required for the installation from the Front Panel Labelling Pack Figure 2 shows where the labels need to be placed 1 2 3 4 5 6 7 8 9 10 F...

Page 3: ...Each unit has 2 pipe holes per channel so if installing a 1 channel unit holes 3 and 4 do not function Use Table 1 to locate the holes required for the installation Figure 8 Pipe Holes Table 1 Pipe H...

Page 4: ...EL 2 FILTER POWER AND ALARM CONNECTIONS CHANNEL 1 FILTER USB PORT SENSOR COVER POSITION FOR TEST MAGNET POSITION FOR TEST MAGNET Exhaust Pipe SAMPLING AREA SAMPLING AREA 5 6 EARTH BAR MOUNT EARTH BAR...

Page 5: ...B connection section later in this guide for more information on this and the FAAST LT Advanced Setup and Control Guide EXTERNAL RESET The default setting for the configurable external input is Device...

Page 6: ...Advanced Protocol Flow Level Test Reset and Disable Buttons 11c FL2022EI 2 Channel Detector ALARM PREALARM MODULE LEVEL SMOKE FAULT FAULT POWER IN P U T S E N S O R AS PIR AT OR E L B A S I D M E T S...

Page 7: ...when initialising POWER FAULT ON Yellow Low power alert high power fault Check the power supply voltage CHANNEL FLOW INDICATORS 1 2 ON Green The LED indicates the air flow for a channel Centre normal...

Page 8: ...operation will cause the unit to enter Service Mode The FILTER LEDs will blink the unit will switch off power to the fans and stops communicating with the fire panel the smoke sensors continue to comm...

Page 9: ...generateconfigurationparameters for correct set up and operation and facilitate commissioning and monitoring of the performance of FAAST LT Aspiration devices PipeIQLT provides a graphical interface o...

Page 10: ...puter in the normal way for your operating system Launching To launch the PipeIQLT application double click the PipeIQLT icon on the desktop Or click Start bottom left corner of the Windows screen and...

Reviews: