Click 

Next

 and follow the on-screen instructions. 

Unless changed, the install wizard will create and store files at the 

following locations:

When installation is complete, the wizard will 

automatically create a shortcut icon on the PC 

desktop.
It will be necessary to re-boot the PC in order to 

run PipeIQLT.

Quitting 

Exiting the program closes the application completely. 
To quit the PipeIQLT application, click 

X

 in the upper-right corner 

of the window.
Or click 

Exit

 from the 

File

 menu.

PipeIQLT can be uninstalled from the computer in the normal way 

for your operating system.

Launching

To launch the PipeIQLT application, double click the 

PipeIQLT

 icon 

on the desktop.
Or
click 

Start

 (bottom left corner of the Windows screen) and then 

select 

PipeIQLT

 from the programs list.

When the application opens, it is possible to start a new project, or 

to monitor or modify an existing project. Use the 

File

 menu to select 

New

 or 

Open

. Choose from the 

Pipe Design

Configuration 

or 

Monitoring

 tabs to enter the required mode.

Set the detector to 

Maintenance 

mode. To communicate with 

a FAAST LT detector, connect the USB port to a PC with an 

appropriate cable.

EN54-20 : 2006

Class A B & C

Aspirating Smoke Detectors

0832

FL2011EI:  0832-CPD-1993 12

FL2012EI:  0832-CPD-1994 12

FL2022EI:  0832-CPD-1995 12

Pittway Tecnologica S.r.l. 

Via Caboto 19/3,

34147 Trieste, Italy

Summary of Contents for FL2011EI

Page 1: ...ator Characteristics Maximum rated switching current under short circuit Is max 0 9A 29V Maximum leakage current IL max with the switch open isolated state 15mA Maximum series impedance with the switc...

Page 2: ...xed in place This allows the installer to choose the language required for the installation from the Front Panel Labelling Pack Figure 2 shows where the labels need to be placed 1 2 3 4 5 6 7 8 9 10 F...

Page 3: ...Each unit has 2 pipe holes per channel so if installing a 1 channel unit holes 3 and 4 do not function Use Table 1 to locate the holes required for the installation Figure 8 Pipe Holes Table 1 Pipe H...

Page 4: ...EL 2 FILTER POWER AND ALARM CONNECTIONS CHANNEL 1 FILTER USB PORT SENSOR COVER POSITION FOR TEST MAGNET POSITION FOR TEST MAGNET Exhaust Pipe SAMPLING AREA SAMPLING AREA 5 6 EARTH BAR MOUNT EARTH BAR...

Page 5: ...B connection section later in this guide for more information on this and the FAAST LT Advanced Setup and Control Guide EXTERNAL RESET The default setting for the configurable external input is Device...

Page 6: ...Advanced Protocol Flow Level Test Reset and Disable Buttons 11c FL2022EI 2 Channel Detector ALARM PREALARM MODULE LEVEL SMOKE FAULT FAULT POWER IN P U T S E N S O R AS PIR AT OR E L B A S I D M E T S...

Page 7: ...when initialising POWER FAULT ON Yellow Low power alert high power fault Check the power supply voltage CHANNEL FLOW INDICATORS 1 2 ON Green The LED indicates the air flow for a channel Centre normal...

Page 8: ...operation will cause the unit to enter Service Mode The FILTER LEDs will blink the unit will switch off power to the fans and stops communicating with the fire panel the smoke sensors continue to comm...

Page 9: ...generateconfigurationparameters for correct set up and operation and facilitate commissioning and monitoring of the performance of FAAST LT Aspiration devices PipeIQLT provides a graphical interface o...

Page 10: ...puter in the normal way for your operating system Launching To launch the PipeIQLT application double click the PipeIQLT icon on the desktop Or click Start bottom left corner of the Windows screen and...

Reviews: