background image

System Sensor warrants its enclosed smoke detector base to be free from defects in ma-
terials and workmanship under normal use and service for a period of three years from 
date of manufacture. System Sensor makes no other express warranty for this smoke 
detector base. No agent, representative, dealer, or employee of the Company has the au-
thority to increase or alter the obligations or limitations of this Warranty. The Company’s 
obligation of this Warranty shall be limited to the repair or replacement of any part of 
the smoke detector base which is found to be defective in materials or workmanship 
under normal use and service during the three year period commencing with the date of 
manufacture. After phoning System Sensor’s toll free number 800-SENSOR2 (736-7672) 
for a Return Authorization number, send defective units postage prepaid to: Honeywell, 

THREE-YEAR LIMITED WARRANTY

12220 Rojas Drive, Suite 700, El Paso TX 79936, USA. Please include a note describing the 
malfunction and suspected cause of failure. The Company shall not be obligated to repair 
or replace units which are found to be defective because of damage, unreasonable use, 
modifications, or alterations occurring after the date of manufacture. In no case shall the 
Company be liable for any consequential or incidental damages for breach of this or any 
other Warranty, expressed or implied whatsoever, even if the loss or damage is caused by 
the Company’s negligence or fault. Some states do not allow the exclusion or limitation of 
incidental or consequential damages, so the above limitation or exclusion may not apply 
to you. This Warranty gives you specific legal rights, and you may also have other rights 
which vary from state to state.

Please refer to insert for the Limitations of Fire Alarm Systems

  4 

I56-3742-001R 

  

©2016 System Sensor. 06-10

firealarmresources.com

Summary of Contents for EBS

Page 1: ...17 4 cm Base Height less sensor 1 61 in 4 1 cm Operating Temperature Range Refer to applicable sensor Operating Temperature Range using the Base Sensor Cross Reference Chart at systemsensor com Operating Humidity Range 10 to 93 relative humidity Non condensing External Supply Electrical Ratings External Supply Voltage 16 to 33 VDC VFWR Standby Current 500 μA maximum Alarm Current 35 mA maximum SLC...

Page 2: ...configured as in Figure 3 reverse the polarity of the external 24VDC sup ply All EBS bases on the loop should sound 2 Latch the detector LED on from the control panel That individual detector s EBS should sound When performing maintenance on connected smoke detectors carefully note the location and address of each removed detector FIGURE 2 MOUNTING C0891 06 Horn Grouping No extra connections are r...

Page 3: ...4 00 FIGURE 5B REMOVING THE DETECTOR HEAD FROM THE BASE C1082 00 SLOT SLOT TAMPER RESIST FEATURE NOTE Do not use the tamper resist feature if the removal tool will be used The detector base includes a tamper resist feature that prevents removal of the detector from the base without using a small screwdriver or similar tool To activate this feature use needle nose pliers to break the tab on the det...

Page 4: ...ve units postage prepaid to Honeywell THREE YEAR LIMITED WARRANTY 12220 Rojas Drive Suite 700 El Paso TX 79936 USA Please include a note describing the malfunction and suspected cause of failure The Company shall not be obligated to repair or replace units which are found to be defective because of damage unreasonable use modifications or alterations occurring after the date of manufacture In no c...

Reviews: