Three-Year Limited Warranty
System Sensor warrants its enclosed heat detector to be free from de-
fects in materials and workmanship under normal use and service for a
period of three years from date of manufacture. System Sensor makes no
other express warranty for this heat detector. No agent, representative,
dealer, or employee of the Company has the authority to increase or alter
the obligations or limitations of this Warranty. The Company’s obligation
of this Warranty shall be limited to the repair or replacement of any part
of the heat detector which is found to be defective in materials or work-
manship under normal use and service during the three year period com-
mencing with the date of manufacture. After phoning System Sensor’s
toll free number 800-SENSOR2 (736-7672) for a Return Authorization
number, send defective units postage prepaid to: System Sensor, Repair
Department, RA #__________, 658 Kitimat Rd., Unit #6, Mississauga,
Ontario, L5N 3T5. Please include a note describing the malfunction and
suspected cause of failure. The Company shall not be obligated to repair
or replace units which are found to be defective because of damage,
unreasonable use, modifications, or alterations occurring after the date
of manufacture. In no case shall the Company be liable for any conse-
quential or incidental damages for breach of this or any other Warranty,
expressed or implied whatsoever, even if the loss or damage is caused by
the Company’s negligence or fault. Some legislations do not allow the ex
-
clusion or limitation of incidental or consequential damages, so the above
limitation or exclusion may not apply to you. This Warranty gives you spe
-
cific legal rights, and you may also have other rights under common law.
WARNING
The Limitations of Property Protection Heat Detectors
Heat detectors do not always detect fires because the fire may be
a slow-smoldering, low-heat type (producing smoke), or because
they may not be near where the fire occurs, or because the heat of
the fire may bypass them.
Heat detectors will not detect smoke, gas,
flames, or combustion particles.
Heat detectors are components in professionally-installed fire alarm
systems.
They will not function if they have been improperly wired
into the fire alarm system or if power to them is cut off for any
reason.
Heat detectors cannot last forever.
They should be tested and
maintained following the instructions in this manual. To be safe, they
should be replaced 5 years after installation.
Refer to CAN/ULC-S536 for application.
This heat detector is designed to
activate and initiate
emergency action,
but will do so only when it is used in conjunction with an authorized fire
alarm system. This detector must be installed in accordance with CAN/
ULC-S524.
Heat detectors will not work without power.
AC or DC-powered smoke
detectors will not work if the power supply is cut off for any reason.
Heat detectors are designed to protect property, not life.
They do not
provide early warning of fire and cannot detect smoke, gas, combustion
particles, or flame. They alarm when temperatures at the heat detector
reach 57°C (135°F). Given the rapid growth of certain types of fires,
heat detectors cannot be expected to provide adequate warning of
fires resulting from smoking in bed, inadequate fire protection practices,
violent explosions, escaping gas, improper storage of flammable liquids
like cleaning solvents, other safety hazards, or arson.