Temperature Measurement
© 2022 System Q Ltd
26
5. Go to live view interface and select thermal channel, click
. Click any position
on the interface to show the real temperature.
7.4 Measure Body Temperature
Steps
:
1. Go to
Configuration-->Temperature Measurement -->Body Thermography
Configuration
.
2. Select thermal channel.
3. Click
Draw Area
, then click the mouse on the black body in live view and save it.
4. Set the black body parameters.
Emissivity: Set the emissivity of black body.
Note
Refer to the emissivity table for reference in the manual or online.
Distance: The straight-line distance between the black body and the device.
Temperature: Enter the temperature of the black body.
Note
If there is no black body in the scene, skip step 3 and 4 .
5. Set
Environmental Temperature Mode
.
Auto
and
Manual
are selectable. In auto
mode, the device detects environment temperature automatically. In manual mode, you
should enter environment temperature manually.
6. Set the body temperature compensation parameters if you need to detect human body
temperature instead of shell temperature.
i.
Enable body temperature compensation
function. ii.
Select the compensation
type.
iii.
In auto mode, the device calculates compensation value automatically. If the
detected body temperature is still inaccuracy, you can set
Manual
Calibration value
.