System air 316293 Installation Manual Download Page 2

1

1.    PRECAUTIONS

CONTENTS

PAGE

When installing the unit in a small room, take measures 

against to keep refrigerant concentration from exceeding 

allowable safety limits in the event of refrigerant leakage.

 

Contact the place of purchase for more information. 

Excessive refrigerant in a closed ambient can lead to oxygen 

deficiency.

Use the attached accessories parts and specified parts 

for installation. 

otherwise, it will cause the set to fall, water  leakage, 

electrical shock and fire.

Install at a strong and firm location which is able to 

withstand the set' s weight. 

If the strength is not enough or installation is not properly 

done, the set will drop to cause injury.

The appliance shall not be installed in the laundry.

Before obtaining access to terminals, all supply circuits 

must be disconnected.

The appliance must be positioned where the plug is 

accessible.

The enclosure of the appliance shall be marked by word, 

or by symbols, with the direction of the fluid flow.

Electrical work should comply with relevant national and 

local standard ,regulations, and this manual . An 

independent circuit and single outlet must be used.

If the electrical circuit capacity is not sufficient or if there is a 

defect in electrical work, electric shocks or fire may result.

Use the specified cable and connect tightly and clamp 

the cable so that no external force will be acted on the 

terminal.

 

If connection or fixing is not perfect, it will cause heat-up or 

fire at the connection.

Wiring routing must be properly arranged so that control 

board cover is fixed properly. 

If control board cover is not fixed perfectly, it will cause 

heat-up at connection point of terminal, fire or electrical 

shock.

If the supply cord is damaged, it must be replaced by the 

manufacture or its service agent or a similarly qualified 

person in order to avoid a hazard.

All pole disconnection switches must be separated by

3 mm in all poles and connected with fixed wiring.

Children and the elderly should not operate this unit 

unless supervised by an adult .

When carrying out piping connection, do not let 

materials enter the refrigeration piping system.

Otherwise, capacaty loss and system pressure rise will result 

and cause equipment damage and human injury.

Do not modify the length of the power supply cord or use 

the extension cord, and do not share the single outlet 

with other electrical appliances.

Otherwise, it will cause fire or electrical shocks.

Natural environmental factors such as typhoons and 

earthquakes,should be considered when installaing.

Improper installation may result in the equipment toppling 

and falling.

To gain full advantage of the unit’s functions and to avoid malfunction

due to mishandling, we recommend that you read this instruction 

manual carefully before use.

The precautions described here are classified as WARNING and 

CAUTION. They both contain important information regarding safety. 

Be sure to observe all precautions without fail. 

WARNING 

Failure to follow these instructions properly may result in 

CAUTION

Failure to observe these instructions properly may result in

personal injury or loss of life.

depending on the circumstances.

 

property damage or personal injury, which may be serious

After reading, keep this manual in convenient place so that you 

can refer to it whenever necessary. If the equipment is transferred 

to a new user, be sure also to hand over the manual.

WARNING 

Only trained and qualified service personnel can 

install, repair or service the equipment.

Improper installation, repair, and maintenance may result 

in electric shocks, short circuits, leaks, fire or other 

damages to the equipment.

Strictly perform installation according to these 

installation instructions. 

If installation is defective, it will cause water leakage, 

electric shocks, or fire.

PRECAUTIONS.......................................................................................1

INSTALLATION INFORMATION................................................................2

ATTACHED FITTINGS.............................................................................3

INDOOR UNIT INSTALLATION.................................................................3

INSTALL THE CONNECTING PIPE..........................................................6

CONNECT THE DRAIN PIPE...................................................................7

WIRING.................................................................................................7

ERROR CODE...................................................................................10

TEST OPERATION...............................................................................10

Summary of Contents for 316293

Page 1: ...SYSVRF2 FLOOR Floor VRF indoor unit INSTALLATION MANUAL GB...

Page 2: ...rated by 3 mm in all poles and connected with fixed wiring Children and the elderly should not operate this unit unless supervised by an adult When carrying out piping connection do not let materials...

Page 3: ...After completing installation make sure that refrigerant does not leak The appliance must be installed in accordance with national wiring regulations To install properly please read this installation...

Page 4: ...technological improvement without further notices Version I Vertical unit with casing with air intake from front and air outlet on top for installation on a wall or on feet on the floor Fig 4 2 Fig 4...

Page 5: ...e square timber traversely over the roof beam then install the hanging screw bolts Fig 4 6 NEW CONCRETE BRICKS Inlaying or embedding the screw bolts FOR ORIGINAL CONCRETE BRICKS Install the hanging ho...

Page 6: ...asurements given in Table 4 2 2 Secure the unit by driving the four fixing screws into suitable masonry plugs Connecting point of refrigerant pipe Liquid side A Connecting point of refrigerant pipe Ga...

Page 7: ...ndoor unit and the outdoor unit Then fasten the nuts at the repair points Notices For Benable pipe The bending angle should not exceed 90 Bending position is preferably in the bendable pipe The larger...

Page 8: ...not let air in which will cause water leakage by condensation 3 Pass the bound connecting pipe through the wall conduit from outside Be careful of the pipe allocation to do no damage to the tubing 3 C...

Page 9: ...or set horsepower 7100W 2 5HP 8000W 3 0HP 5 6 Note The horse power has been set before leaving the factory anyone can t modify it except the maintenance person 7 5 Terminal Board Diagram Please refer...

Page 10: ...is 6 C under heat mode default 01 means temp compensation value is 2 C under heat mode 10 means temp compensation value is 4 C under heat mode 11 means temp compensation value is 0 C under heat mode f...

Page 11: ...ting in the Owner s Manual 1 The indoor unit a Whether the switch on the remote controller works well b Whether the buttons on the remote controller works well c Whether the air flow louver moves norm...

Page 12: ...16126000002887 V4 0...

Reviews: