![Sysmac Omron F430-F Series Connection Manual Download Page 17](http://html1.mh-extra.com/html/sysmac/omron-f430-f-series/omron-f430-f-series_connection-manual_1421661017.webp)
16
6.4. Tag Set
The Tag set settings to perform Tag data links is shown below.
The data within the Tag set is in ascending order with the following OUT No. and IN No.
■ Output Area (Controller → Smart Camera)
Originator Variable (Tag set name)
Data size (byte)
EIPOutput
320
OUT No.
Global Variable Name (Tag
Name)
Data size (byte)
1
EIPOutput
320
■ Input Area (Smart Camera → Controller)
Originator Variable (Tag set name)
Data size (byte)
EIPInput
320
IN No.
Global Variable Name (Tag
Name)
Data size (byte)
1
EIPInput
320
6.5. Tag Data Link Table
The content of tag data link table settings (connection settings) is shown below.
The values shown in the red frame are those values defined in the EDS file of the smart
camera.
Connection name
Connection I/O Type
RPI (ms)
Timeout
default_001
IO320
50.0
RPI x 4
Connection
I/O Type
Input /
Output
Target Variable
Size
(Byte)
Originator Variable
(Tag set name)
Size
(Byte)
Connection
type
IO320
Input
102
320
EIPInput
320
Point to
Point
connection
Output
114
320
EIPOutput
320
Point to
Point
connection