SY120SA SINGLE DOOR CONTROLLER
- 6 -
6. System DO Function Setup
【
this function needs to operate under login status
】
Enter FUN +
7
1
+
【
K
】
+
【
F
】
+
【
TTT
】
+ EN
。
K
:
The DO sequent number which wants to set up;
K = 1 as electric lock DO,
K = 2 as relay DO,
K = 3 as expand relay DO,
K = 4 as pre-save DO
F
:
DO purpose number, please refer the below DO purpose table.
TTT
:
DO action time set up, range: 000
~
255, unit: second; default electric lock DO for 5 seconds,
relay DO for 2seconds.
DO Purpose Table
Numbe
r
Purpose Notation
0 Not
use
1
Open door control
(electric lock DO preset)
2
Doorbell contact output
(relay DO preset)
3
Burglar alarm output
Deploy and withdraw controlled
4
Alarm contact output
Use withdraw to cancel alarm
5
Anti-force contact output
Use[FUN][4][4]to cancel anti-force
alarm
※
Action time set “0” for keeps action until relief
Example
:
【
set up expand open door button, action time 3seconds (set up DI and DO together)
】
DI
:
FUN +
6
1
+
1
+
2
+
0
+ EN
DO
:
FUN +
7
1
+
2
+
1
+
0
0
3
+ EN