SYR SYR-Safe-T Instructions Of Use Download Page 5

Menu

Values

Leakage protec-

tion (LE)

-- (deactivated)

1 - 15 (100 - 1500 

liters) 

(Factory set to: 4)

Vacation leakage 

protection (UL)

-- (deactivated)

1 - 10 (10 - 100 liters) 

Factory set to: 10

Stop valve  

(AB)

P1 (OPEN), P2 (CLO-

SED) 

Factory setting: 

P1 (OPEN)

5

5.3 Deactivating the leakage 

protection

To deactivate the leakage protection, unlock the 

keyboard, if necessary.

Press the   key until reaching the menu „LE“.

Set the desired value by means of the   or   

key.

The system allows for the following settings:

Press  the 

  key  to  validate  and  save  the 

changes. 

Press the    key to display the current setting.

Set the desired value by means of the    - or 

 key.

Press the    key to save the settings.

Note:  The  leakage  protection  system  is 

automatically reactivated after 8 hours!

Should  a  tighter  supervision  be  needed  for  a 

certain time, use the vacation leakage protection 

mode. 

This  setting  implies  that  only  minor  water 

quantities  between  10  and  100  liters  will  be 

drawn off without interruption. 

When the indicated water quantity is exceeded, 

a leakage problem is suspected → Message A5 

is displayed.

5.4 Vacation leakage

 protection

Summary of Contents for SYR-Safe-T

Page 1: ...Instructions of use...

Page 2: ...ge protection 4 5 3 Deactivating the leak protection 5 5 4 Vacation leakage protection 5 5 5 Setting the vacation leakage protection 6 5 6 Deactivating the vacation leakage protection 6 5 7 Stop valve...

Page 3: ...into the normal operation mode Make sure that the battery block is correctly po sitioned in the compartment against the internal back wall Close the battery door As an option you can also connect the...

Page 4: ...of the following criteria be exceeded the device suspects a leakage problem and closes the main isolating valve In case the water quantity flown without interruption exceeds the set limit for the volu...

Page 5: ...lows for the following settings Press the key to validate and save the changes Press the key to display the current setting Set the desired value by means of the or key Press the key to save the setti...

Page 6: ...key to save the settings Press the key again to display the current setting of the vacation leakage protection Press the key until the vacation leakage protection is displayed 5 6 Deactivating the vac...

Page 7: ...play the current sta tus of the leakage protection s stop valve Press the key to display the menu of the lea kage protection s stop valve 5 7 Stop valve In order to change the stop valve s position un...

Page 8: ...e vacation supervision use the following function When no water is drawn off during 48 hours the main stop valve isolates the system for 3 minutes When the stop valve opens again after 3 minutes the d...

Page 9: ...ply when the flow rate exceeds 3500 l h Save the change by pressing the key 6 5 Unlocking the device The next step leads to the menu allowing to un lock the device When the SYR Safe T has isolated the...

Page 10: ...ired status by means of the or key and save the change by pressing the key 6 9 Contact 2 The contact 2 offers many connection possibilities You can connect for instance floor sensors or temperature pr...

Page 11: ...ise the installation with full Hc or re stricted only floor sensor Hd supervision Save the change by pressing the key Press the or key to define the conditions When selecting the restricted supervisio...

Page 12: ...e display 8 Emergency unlock function The emergency unlock function is designed to unlock the system manually in case the SYR Safe T isolates the installation and a power fai lure occurs at the same t...

Page 13: ...s to restart the device 8 1 page 11 Mount the control unit and secure it with the clamp Put the two insulating covers back into place As the position has been changed manually with the emergency unloc...

Page 14: ...alified installers are authorised to install and service the device Do not clean synthetic parts with solvent based detergents Protect the device and the electronic system against frost When submitted...

Page 15: ...Type SYR Safe T Leakage protection module Nominal size DN 20 32 Dimensions T 108 mm t 24 mm T1 105 mm t1 76 mm H 307 mm h 174 mm B 120 mm 15 12 Dimensions...

Page 16: ...has been exceeded Press the key to open the stop valve and eliminate the leakage problem The system has identified a leakage problem at contact IN1 floor sensor Press the key to open the stop valve an...