SYR SYR-Safe-T Instructions Of Use Download Page 3

Symbol

Key

Meaning

Mode To validate entries

Down To decrease values

Up

To increase values

3

Exchange the batteries every two years at 

the latest!

Do not use accumulators!

3.1 Initial operation

As  soon  as  the  batteries  are  inserted,  the 

system first goes into the closed position. 

The display shows the message IO.

When  pressing  the    -  key,  the  system  goes 

into the open position. 

The  system  is  open  when  the  message  10 

flashes  in  the  display. Afterwards,  it  goes  into 

the normal operation mode.

Make sure that the battery block is correctly po-

sitioned in the compartment against the internal 

back wall. 

Close the battery door.

As  an  option,  you  can  also  connect  the  SYR 

Safe-T with a mains plug (1100.00.900).

4. General operation

The  display  consists  of  two  digits  and  three 

press buttons (mode, down and up key).

Use the   or   key to adjust the various values. 

Use the   key to confirm and save the values or 

to activate another menu.  

4.1 Unlocking the keyboard

When  the  Safe-T  is  exclusively  battery-

operated, press any key to activate the display. 

It will automatically disconnect after 30 seconds. 

The device‘s keyboard is locked. 

Summary of Contents for SYR-Safe-T

Page 1: ...Instructions of use...

Page 2: ...ge protection 4 5 3 Deactivating the leak protection 5 5 4 Vacation leakage protection 5 5 5 Setting the vacation leakage protection 6 5 6 Deactivating the vacation leakage protection 6 5 7 Stop valve...

Page 3: ...into the normal operation mode Make sure that the battery block is correctly po sitioned in the compartment against the internal back wall Close the battery door As an option you can also connect the...

Page 4: ...of the following criteria be exceeded the device suspects a leakage problem and closes the main isolating valve In case the water quantity flown without interruption exceeds the set limit for the volu...

Page 5: ...lows for the following settings Press the key to validate and save the changes Press the key to display the current setting Set the desired value by means of the or key Press the key to save the setti...

Page 6: ...key to save the settings Press the key again to display the current setting of the vacation leakage protection Press the key until the vacation leakage protection is displayed 5 6 Deactivating the vac...

Page 7: ...play the current sta tus of the leakage protection s stop valve Press the key to display the menu of the lea kage protection s stop valve 5 7 Stop valve In order to change the stop valve s position un...

Page 8: ...e vacation supervision use the following function When no water is drawn off during 48 hours the main stop valve isolates the system for 3 minutes When the stop valve opens again after 3 minutes the d...

Page 9: ...ply when the flow rate exceeds 3500 l h Save the change by pressing the key 6 5 Unlocking the device The next step leads to the menu allowing to un lock the device When the SYR Safe T has isolated the...

Page 10: ...ired status by means of the or key and save the change by pressing the key 6 9 Contact 2 The contact 2 offers many connection possibilities You can connect for instance floor sensors or temperature pr...

Page 11: ...ise the installation with full Hc or re stricted only floor sensor Hd supervision Save the change by pressing the key Press the or key to define the conditions When selecting the restricted supervisio...

Page 12: ...e display 8 Emergency unlock function The emergency unlock function is designed to unlock the system manually in case the SYR Safe T isolates the installation and a power fai lure occurs at the same t...

Page 13: ...s to restart the device 8 1 page 11 Mount the control unit and secure it with the clamp Put the two insulating covers back into place As the position has been changed manually with the emergency unloc...

Page 14: ...alified installers are authorised to install and service the device Do not clean synthetic parts with solvent based detergents Protect the device and the electronic system against frost When submitted...

Page 15: ...Type SYR Safe T Leakage protection module Nominal size DN 20 32 Dimensions T 108 mm t 24 mm T1 105 mm t1 76 mm H 307 mm h 174 mm B 120 mm 15 12 Dimensions...

Page 16: ...has been exceeded Press the key to open the stop valve and eliminate the leakage problem The system has identified a leakage problem at contact IN1 floor sensor Press the key to open the stop valve an...

Reviews: