10 – 1
d
iagrams
10
©
IT
4000
9.4000.04
1148
10 d
iagrams
Fig. 1 Pressure loss in operating position
Fig. 2 Draw-off quantity per day
Pressure loss in operating position (pos. 1) with a raw water hardness of 20 °dH (German
hardness degree) and a blended water hardness of 8 °dH in dependence on the volume-
tric flow rate.
Max possible draw-off quantity per day depending on the raw water hardness with a blen-
ded water hardness of 8 °dH (German hardness degree).