background image

                                                   

Synway Information Engineering Co., Ltd

 

During software run

als if the board is 

working pro

r software detects 

abno

g board. The new 

boar

previous, or software 

parameters will have to 
mov
anytime with

Note

time, the run indicator blinks at 1-second interv

perly, or, it will go on and off at irregular intervals if the drive

rmal behavior by the board and prompt users to replace the existin

d should be of the same model and placed in the same slot as the 

be reconfigured. If the rear connection panel is used, remember to 

e it along with the voice board. The rear connection panel can be hot-swapped at 

out interrupting runtime. 

:

 Releasing the bottom handle at runtime will cause your board to stop operating! 

SHT-16B-CT/cPCI 2.0, SHT-16B-CT/cPCI/FAX (MP3) 2.0 Hardware Manual 

(Version 2.2) 

  Page 19 

Summary of Contents for SHT-16B-CT/cPCI 2.0

Page 1: ...Synway CTI Series SHT 16B CT cPCI 2 0 SHT 16B CT cPCI FAX 2 0 SHT 16B CT cPCI MP3 2 0 Analog Voice Board Version 2 2 Synway Information Engineering Co Ltd www synway net...

Page 2: ...eration Principle 4 1 4 Functional Modules 4 Chapter 2 Installation 7 2 1 Hardware Structure 7 2 2 System Requirements 12 2 3 Installation Procedure 13 2 4 Precaution on Hot swap Operation at Runtime...

Page 3: ...ll rights to modify this document without prior notice Please contact Synway for the latest version of this document before placing an order Synway has made every effort to ensure the accuracy of this...

Page 4: ...on panel and added illustrations of boards and modules for better understanding Version 2 0 2009 6 Changes Added the CT_EN jumper and the description on it Version 2 1 Version 2 2 2011 11 Changes adde...

Page 5: ...rding operation z DTMF transmission and detection z Automatic line voltage detection z Automatically checks the number and the type of the modules on the board 1 2 Features z CompactPCI 2 1 Bus Suppor...

Page 6: ...ptionally built on the rear connection panel supplies the internal ringing current and battery feed provided that it is working with the 48V IPC power supply z Programmable Tone Detector Detects singl...

Page 7: ...ber Each board has a unique hardware serial number written in the firmware to distinguish itself from other boards and prevent piracy The number is available via an easy function call with application...

Page 8: ...from Central Office Terminal COT with ability to detect line voltage diagnose line failure and judge the on hook off hook state of the station phone which is linked with it See Figure 2 6 and Figure 2...

Page 9: ...tion of its corresponding channel with a magnet phone line so that to simulate the functions provided by magnet telephones Refer to Figure 2 14 and Figure 2 15 for details z EM2V100 Module A single EM...

Page 10: ...Vn0 5 E1 6 M1 7 Vp1 8 Vn1 See below for the pin definition of a single RJ11 Pin No Pin Definition for EM2V100 1 E0 2 M0 3 Vp0 4 Vn0 Connect to EM Interface Carrying 2 line Voice Data E EM2V100 M T R...

Page 11: ...Slot 1 Ch9 Ch10 Ch1 Ch2 Module Slot 6 Module Slot 2 Ch11 Ch12 Ch3 Ch4 Module Slot 7 Module Slot 3 Ch13 Ch14 Ch5 Ch6 Module Slot 8 Module Slot 4 Ch15 Ch16 Ch7 Ch8 cPCI Connector with Alignment Pin cPC...

Page 12: ...hoose SHT 16B B2 cPCI and properly configure the jumpers on the SHT 16B CT cPCI 2 0 SHT 16B CT cPCI FAX 2 0 or SHT 16B CT cPCI MP3 2 0 board before using this rear connection panel 2 When using the IP...

Page 13: ...on the SHT 16B CT cPCI 2 0 board and its rear connection panel Figure 2 5 Indicators nection Panel The above indicators and interfaces function as follo Interfaces on Board and Rear Con ws Indicators...

Page 14: ...44 Connector links all the 16 voice paths channels P R An interface for ringing current and battery feed power supply SPK Audio output interface which is a 3 5 stereo jack z Analog Trunk Module Figure...

Page 15: ...Front View nk Statio Figure 2 10 Front View Model Clamp Hole Clamp Hole CSCMK Clamp Hole Model Version Date Clamp Hole 2 0R T Ver xx xxxxxx Model Clamp Hole Clamp Hole R T Clamp Hole Model Version Dat...

Page 16: ...quirements Figure 2 15 Rear View CPU 300MHz Intel Pentium or above Memory 256M or more HD Depends on individual requirements Supported Operating Systems r s Manual pdf Refer to SynCTI Programme Clamp...

Page 17: ...ith the board If using the IPC mainboard to supply both the ringing current and the battery feed you should use the jumper cap to short circuit the 2nd and 3rd pins on JK10 the 3rd and 4th pins on JK1...

Page 18: ...t them with 16 voice channels via a Note Users should confirm the jumper configuration or reset the jumpers depending real situation before using these boards p 3 Fit the board and the rear connection...

Page 19: ...25 17 7 10 15 2 24 16 8 9 16 1 Table 2 5 Pin Description for DB44 11 jack can be connected to lines via a 2 way hub Notes The remaining few pins on DB44 unmentioned above stay unused Each RJ See Tabl...

Page 20: ...se the EM2V100 modules there are two situations as shown below 1 Used as an EM trunk channel carrying 2 line voice data In such situation as a s odule is used as an E unk chan l carrying 2 line voice...

Page 21: ...o the remote end while that pair on the second module is suggested not to be connected Step 7 Connect to the ringing current battery feed power supply rent and the battery feed If you are using the ex...

Page 22: ...esistance 2 4 The insta the oper i e upon releasing the board to wait for the hot swap blue lamp to light up before pulling it out from the slot Also note to never remove the board when it is being in...

Page 23: ...lar intervals if the drive rmal behavior by the board and prompt users to replace the existin d should be of the same model and placed in the same slot as the be reconfigured If the rear connection pa...

Page 24: ...ratio 38dB Echo suppression 40dB Maximum System Capacity Up to 10 boards concurrently per system up to 16 channels per board Power Requirements 12V DC 80mA Maximum power consumption 12W Impedance Inpu...

Page 25: ...enter No 3756 ou P R China 3100 860561 0923 ort Synway Information Ltd Nanhuan Road Binjiang 53 District Hangzh Tel 86 571 88 Fax 86 571 8885 Technical Supp Tel 86 571 88864579 86 13735549651 rt sanhu...

Reviews: