Operations 

Batteries must be fresh and properly loaded before start operation. 

4.1

 

Keyboard Operations

 

The keypad of the 8000 Portable Data Terminal has 21 keys. The functions of some special keys are 
as follows: 

 
SCAN 

 

        

Scan a barcode

Press this button will trigger the scanner to read a barcode if the scanner port is 
enabled. 

 
ENTER                  

Enter

There are two enter keys on the side of the scan key. Normally the enter keys are 
used for command execution or input confirmation. 
 

ESC

  

                

Escape

Usually this key is used to stop and exit current operation. 
 

BS   

 

 

Back Space

.  

If this key is being pressed down longer than one second, a 

clea

r

 code will be 

sent. 
 

ALPHA   

        

The toggle key for Alphabet / Numeral input

When the system is in alpha-mode, a small icon will be shown on the display and 
each  numeral  key  can  be  used  to  generate  one  of  the  three  capital  letters.  For 
example, numeral 

2

  can  be used to  produce 

A

B

  or 

C

. Pressing the same key 

twice  within  one  second,  will  call  the  letter  B.  Pressing  the  same  key  without 
halting  longer  than  one  second,  will  cause  the  three  letters  to  be  shown  in  a 
circulating way. Only when stop pressing the key for longer than one second or 
pressing another key, will the system send the real key code to  the application 
program. 

 

FN                   

 

The function key

.  

This key cannot be activated alone, it must be pressed with one numeral key at 
the same time.  For  example, 

FN

 + 

1

  generates  function #

1

FN

 + 

2

  generates 

function  #

2

,  etc  (up  to  9  functions).  Also,  this  key  can  be  combined  with  the 

UP/DOWN

 arrow keys to adjust the contrast of the LCD. And when this key is 

combined with the 

ENTER

 key, it will turn ON/OFF the backlight. 

 

POWER  

 

Power On/Off

To  prevent  a  faulty  push,  it  needs  about  1.5  sec  continuous  pressing  to  turn 
On/Off the power. 

 

4.2

 

Application mode 

This  is  the  default  operation  mode  when  turning  on  the  power.  The  operation  depends  on  the 
application module. Please refer to section 3.4. 

Summary of Contents for CipherLab 80x0 series

Page 1: ...s Guide Version 1 10 Copyright 2003 Syntech Information Co Ltd SYNTECH INFORMATION CO LTD Head Office 8F No 210 Ta Tung Rd Sec 3 Hsi Chih Taipei Hsien Taiwan Tel 886 2 8647 1166 Fax 886 2 8647 1100 e mail support cipherlab com tw http www cipherlab com tw ...

Page 2: ...2 8 Keypad 3 2 9 Indicator 3 2 10 Communication 3 2 11 Software 4 2 12 Accessories 4 3 Software Architecture 5 3 1 Kernel Application Manager 5 3 2 System 6 3 3 Application 11 3 4 Programming the terminal 11 3 5 Programming the communication cradle 11 4 Operations 12 4 1 Keyboard Operations 12 4 2 Application mode 12 4 3 System mode 13 4 4 Kernel mode 13 4 5 Application Manager 13 5 Troubleshootin...

Page 3: ...nce with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following me...

Page 4: ...ck Shock resistance 1 2m drop onto concrete 2 3 Physical Dimensions 80x0 Series 122mm L x 56mm W x 25mm H Dimensions 80x1 Series 122mm L x 56mm W x 30mm H Weight 80x0 Series 130g including battery Weight 80x1 Series 135g including battery Housing color Black Housing material ABS 2 4 CPU Toshiba 16 bit CMOS type CPU Tunable clock up to 22MHz 2 5 Memory Program memory 1 M Bytes flash Data memory 1M ...

Page 5: ...on Serial IR Baud rate up to 115200 bps Standard IrDA Baud rate up to 115200 bps Bluetooth Class 1 8061 Frequency Range 2 4020 2 4835 GHz Modulation GFSK Profiles BNEP SPP Data Rate 433 Kbps Coverage 250M line of sight Maximum Output Power 100mW Standard Bluetooth spec V1 1 Acoustic Coupler 8020 8021 Modulation Type Bell202 FSK Sound Frequency 1 2KHz 5 2 2KHz 5 Data Rate 1200 bps 802 11b 8071 Freq...

Page 6: ...S Programming Tools C compiler BASIC compiler and a Windows based Application Generator 2 12 Accessories IR Communication Cradle Modem Cradle Charging Communication Cradle Li ion Rechargeable Battery Pack 3560 Bluetooth Access Point USB Communication Cradle ...

Page 7: ... the kernel menu if there is no application program exists then upon power up the terminal the following Application Manager s menu will be shown Download To download application programs SHX BASIC run time BC8000 SHX BASIC programs SYN or font files 8xxx XX SHX to the terminal There are 6 resident locations and one Active Memory i e at most 7 programs can be downloaded to the terminal But only th...

Page 8: ...ghth speed and sixteenth speed Default Full speed 4 Auto Off Set time threshold for automatically power off when no operation is taking place during that specified period If this value is set to zero this function will be disabled Default 10 minutes 5 Power On Mode There are two possible selections Program Resume which starts from the program being used during the last session before the last powe...

Page 9: ...n with numeral keys 5 Memory To test the data memory SRAM Note after the test the contents of the memory space will be wiped out 4 Memory 1 Size Information Information includes sizes of the base memory SRAM memory card SRAM and program memory FLASH in the unit of kilobytes 2 Initialize To initialize the data memory SRAM Note the contents of the data space will be wiped out after memory initializa...

Page 10: ...le 2 SubNet Mask The number used to identify the IP sub network indicating whether the IP address can be recognized on the LAN Default 255 255 128 0 3 Local IPAddress The address which identifies a location of the terminal on the network must be unique Default 0 0 0 0 4 Default Gateway the Gateway IP address is the IP address of a local router in between the forwarding node and the remote network ...

Page 11: ... with high network traffic select a long preamble when the network traffic is low Default 1 Long 4 Security 1 Authentication 802 11b supports two subtypes of network authentication services open system and shared key Open system authentication is used when no authentication is required Under Share Key Authentication it involves a shared secret key to authenticate the station to the AP access point...

Page 12: ...rminal only supports EAP MD5 When these features are implemented a wireless client that associates with an access point cannot gain access to the network until the user performs a network logon Therefore Identity and Password are needed when EAP is enabled EAP Setting EAP ID EAP Password 5 Echo Tests The terminal will echo the received data from the client or server and also signals a beep The fun...

Page 13: ...information please refer to Application Generator User s Guide 3 4 Programming the terminal There are three software tools available for developing application programs for the terminal 1 The Application Generator 2 The BASIC Compiler 3 The C Compiler For detailed information please contact Syntech Information Co Ltd 3 5 Programming the communication cradle The communication cradle of the 80x0 80x...

Page 14: ... For example numeral 2 can be used to produce A B or C Pressing the same key twice within one second will call the letter B Pressing the same key without halting longer than one second will cause the three letters to be shown in a circulating way Only when stop pressing the key for longer than one second or pressing another key will the system send the real key code to the application program FN T...

Page 15: ...e refer to section 3 1 4 5 Application Manager Although the Application Manager is part of the kernel to enter it you need to press 8 and POWER key simultaneously Or if the application program does not exist the unit will automatically go to the Application Manager s menu upon power up The three services Download Activate and Upload provided by the Application Manager are explained in Section 3 1 ...

Page 16: ... Terminal s c Keypad does not work properly Turn off the power then press the 7 9 and POWER keys simultaneously to enter the system menu From the system menu select the Test and then its sub item KBD Perform the key in test If problem persists call for service d Scanner does not scan Check if the barcode reader is enabled or Check if battery low indicator is shown on the LCD display If yes change ...

Reviews: