14
8)
Upon completion of fluid re-filling, check vehicle’s transmission fluid level as specified.
Add or extract fluid to achieve proper
fluid level by selecting the appropriate ADD FLUID or
REMOVE FLUID buttons on the control panel. Additions displayed in NEW fluid display
while removals are displayed in USED fluid display.
This amount can be increased or decreased using the “ + ” or “ - “ buttons on the control panel.
The desired amount will be extracted or added upon depressing ADD FLUID or REMOVE
FLUID button the
second
time. Repeat this procedure until the proper level is maintained.
NOTE:
If NEW fluid tank does not have enough fluid to perform the ADD FLUID function or
USED fluid tank does not have enough capacity to perform the REMOVE FLUID
function, the appropriate LED will flash and beep indicating LOW TANK LEVEL in
NEW tank and/or HIGH TANK LEVEL in USED tank. Take the appropriate action
to correct and then repeat Step 8.
The EMPTY USED function is used to empty used transmission fluid into a bulk waste fluid storage
tank for proper disposal. Depressing the EMPTY USED button on the control panel starts the process
and the flow can be controlled with the manual ball valve at the end of the yellow hose. The internal
pump is equipped with an internal pressure switch that shuts off the pump should blockage or “dead-
heading” occur.
The USED TANK level sensor will end the process automatically when tank level nears zero in tank.
Also, depressing the STOP button on control panel will stop the process.
Empty Used Tank
The EMPTY NEW function is used to empty new transmission fluid contained in the NEW TANK into
an appropriate storage container. This allows the use of other types of transmission fluid in the unit
while minimizing cross contamination of fluid types.
Insert and secure the dipstick extraction wand into the storage container. Depress the EMPTY NEW
button on the control panel and the new fluid will begin to pump out of the unit into storage container.
The fluid will continue to flow until the level sensor in the NEW TANK nears zero quarts in the tank.
Also, depressing the STOP button on the control panel will stop this procedure.
Empty New Tank
The dipstick extraction wand drippings are collected in a small reservoir inside the unit. To periodically
empty the waste fluid, (check for high fluid level on dipstick wand) insert DIPSTICK extraction wand
all the way into wand storage hole. Select DIPSTICK mode, press DRAIN PAN and the unit will empty
the reservoir. After twenty seconds of no fluid level change the unit will stop automatically. Press
STOP button to reset unit.
Empty Hose and Dipstick Wand Drippage