12. Operation (Temperature Control)

1)  Turn shower handle counter-clockwise 

approximately 1/4 turn to put valve in 

cold position (FIGURE 12.1).

2)  Turn shower handle counter- clockwise 

approximately 1/2 turn to put valve in 

warm position (FIGURE 12.2).

3)  Turn shower handle counter- clockwise 

approximately 3/4 turn to put valve in 

hot position (FIGURE 12.3).

FIGURE 12.1

FIGURE 12.2

FIGURE 12.3

13. Operation (Dual Outlet Diverter Control)

1)  Cartridge is factory set to divert to 

function 1 (FIGURE 13.1). 

2)  Turn handle to position 2 to divert to 

function 2 (FIGURE 13.2).

3)  Turn handle to position 3 to share 

functions 1 and 2 (FIGURE 13.3).

FIGURE 13.1

FIGURE 13.2

FIGURE 13.3

14. Operation (Triple Outlet Diverter Control)

1)  Cartridge is factory set to divert to 

function 1 (FIGURE 14.1).

2)  Turn handle to position 2 to divert to 

function 2 (FIGURE 14.2).

3)  Turn handle to position 3 to divert to 

function 3 (FIGURE 14.3).

FIGURE 14.1

FIGURE 14.2

FIGURE 14.3

4)  Turn handle to position 4 to share 

functions 2 and 3 (FIGURE 14.4).

5)  Turn handle to position 5 to share 

functions 1 and 3 (FIGURE 14.5).

6)  Turn handle to position 6 to share 

functions 1 and 2 (FIGURE 14.6).

FIGURE 14.4

FIGURE 14.5

FIGURE 14.6

Note:

 Additional handle positions for      

          same output are illustrated.

Summary of Contents for Sereno 4300-TRM

Page 1: ...ted Lifetime to the original end purchaser in consumer residential installations 5 Years for industrial commercial installations Refer to www symmons com warranty for complete warranty information Go to www symmons com register to register your Symmons product TRIM TA 10 T 12A 4300TRMTC Shower Valve Trim 4301TRMTC Shower Trim 4303TRMTC Hand Shower Trim 4305TRMTC Shower Hand Shower Trim 4306TRMTC T...

Page 2: ...s subject to change without notice Phillips Screwdriver Adjustable Wrench Safety Glasses Thread Seal Tape FIGURE 1 2 Dimensions Measurements A Ø 2 1 4 57 mm B Ø 2 1 4 57 mm C 6 152 mm D 9 1 4 235 mm E Female 1 2 IPS thread must be recessed 7 8 from finished wall F 6 152 mm right or left G 7 178 mm H 5 127 mm I 77 1956 mm J 4 3 4 121 mm K 5 3 4 146 mm L 9 1 4 235 mm M 10 254 mm N Ø 2 3 8 60 mm O 43...

Page 3: ...del Numbers Ending in TRMTC 1 Check for leaks around the valve assembly and all pipe fittings Flow control spindle TA 10 and cap assembly T 12A will come factory assembled for all model numbers ending in TRMTC When ready to remove Test Cap and install trim follow the instructions below 2 Remove test cap from valve FIGURE 4 1 3 If system is dirty flush valve 4 Thread flow control spindle and cap as...

Page 4: ...X A B C K K L G H I J D E F G H I D E F M M O Q P R S T U W V N EF 109 Order in line vacuum breaker EF 109 for hand shower systems without dual checks 7 Parts Breakdown Notes 1 Append appropriate suffix for premium finish 2 Append appropriate flow rate to showerhead or hand shower for low flow 3 Apply a bead of silicone around the perimeter of all shower trim installed flush to the finished wall L...

Page 5: ...nting screws FIGURE 9 1 FIGURE 9 1 FIGURE 9 2 4 Install handle to diverter valve Secure with star washer set screw and plug button FIGURE 9 4 3 Install dome cover and lock nut to valve by turning clockwise FIGURE 9 3 FIGURE 9 3 1 Attach shower arm and flange to shower pipe Turn clockwise to tighten FIGURE 10 1 2 Install showerhead to shower arm Turn clockwise to tighten FIGURE 10 2 3 Install tub s...

Page 6: ...ption Place mounting plate in position mark and drill 1 8 pilot holes into stud 3 Install mounting plate Secure with two screws Replace cradle mount cover FIGURE 11 3 Note Mounting plate center tabs must be horizontal for installation FIGURE 11 5 1 3 FIGURE 11 2 2 1 3 FIGURE 11 3 2 5 Install wall elbow and flange to recessed pipe fitting Turn elbow clockwise to tighten FIGURE 11 5 FIGURE 11 6 FIGU...

Page 7: ... 2 to divert to function 2 FIGURE 13 2 3 Turn handle to position 3 to share functions 1 and 2 FIGURE 13 3 FIGURE 13 1 FIGURE 13 2 FIGURE 13 3 14 Operation Triple Outlet Diverter Control 1 Cartridge is factory set to divert to function 1 FIGURE 14 1 2 Turn handle to position 2 to divert to function 2 FIGURE 14 2 3 Turn handle to position 3 to divert to function 3 FIGURE 14 3 FIGURE 14 1 FIGURE 14 2...

Page 8: ...emicals including lead which is known to the state of California to cause cancer birth defects or other reproductive harm For more information go to www P65Warnings ca gov 15 Troubleshooting Chart Problem Cause Solution Finish is spotting Elements in water supply may cause water staining on finish Clean finished trim area with a soft cloth using mild soap and water or a non abrasive cleaner and th...

Reviews: