Symmons Sereno 4300-TRM Installation & Operation Instructions Download Page 3

3

3. Parts Breakdown (Model Numbers Ending in TRMTC)

5. Installation - Adjust Packing Nut 

(Model Numbers Ending in TRMTC)

1) Turn hot and cold supplies on.  Valve will not operate unless both hot and cold water supply pressures are on.

2)  Place handle over flow control spindle.

3)  Tighten packing nut for positive frictional resistance as handle is rotated from shut-off position across adjustment range.

6. Installation - Setting Limit Stop Screw 

(Model Numbers Ending in TRMTC)

1) Turn hot and cold supplies on.  Valve will not operate unless both hot and cold water supply pressures are on.

2)  Place handle on flow control spindle and open valve to maximum desired temperature.

3)  Turn limit stop screw clockwise until it seats.

     WARNING:

  Failure to adjust limit stop screw properly may result in serious scalding.

The temperature limit stop screw limits valve handle from being turned to maximum position resulting in excessive hot 

water discharge temperatures.

4. Installation - Remove Test Cap 

(Model Numbers Ending in TRMTC)

1)  Check for leaks around the valve assembly and all pipe 

fittings.

Flow control spindle (TA-10) and cap assembly (T-12A) will 

come factory assembled for all model numbers ending in 

TRMTC

.  When ready to remove Test Cap and install trim, 

follow the instructions below:

2)  Remove test cap from valve (FIGURE 4.1).

3)  If system is dirty, flush valve. 

4)  Thread flow control spindle and cap assembly into valve 

body.  Turn clockwise to secure to valve (FIGURE 4.2).

FIGURE 4.1

FIGURE 4.2

LIMIT STOP 

SCREW

2

1

PACKING 

NUT

FIGURE 3

Replacement Parts

Item

Description

Part Number

1

Cap Assy.

T-12A

2

Flow Control Spindle

TA-10

IMPORTANT:

  Model numbers ending in 

TRMTC

 

coordinate with Temptrol pressure balancing valves 

ordered with Test Cap.  The Test Cap is used to 

allow pressurization of system.  

Do not

 remove 

test cap from valve during wall construction, 

installation of valve or pressurization of system.

  WARNINGS:

1.  Do not expose valve with test cap to heat 

for longer than 2 minutes when soldering 

copper tubing.  Doing so may damage the 

internal components of the valve and will 

void the product warranty.

2.  Ensure test cap is 

tightened securely 

after 

soldering valve body.

Summary of Contents for Sereno 4300-TRM

Page 1: ...ted Lifetime to the original end purchaser in consumer residential installations 5 Years for industrial commercial installations Refer to www symmons com warranty for complete warranty information Go to www symmons com register to register your Symmons product TRIM TA 10 T 12A 4300TRMTC Shower Valve Trim 4301TRMTC Shower Trim 4303TRMTC Hand Shower Trim 4305TRMTC Shower Hand Shower Trim 4306TRMTC T...

Page 2: ...s subject to change without notice Phillips Screwdriver Adjustable Wrench Safety Glasses Thread Seal Tape FIGURE 1 2 Dimensions Measurements A Ø 2 1 4 57 mm B Ø 2 1 4 57 mm C 6 152 mm D 9 1 4 235 mm E Female 1 2 IPS thread must be recessed 7 8 from finished wall F 6 152 mm right or left G 7 178 mm H 5 127 mm I 77 1956 mm J 4 3 4 121 mm K 5 3 4 146 mm L 9 1 4 235 mm M 10 254 mm N Ø 2 3 8 60 mm O 43...

Page 3: ...del Numbers Ending in TRMTC 1 Check for leaks around the valve assembly and all pipe fittings Flow control spindle TA 10 and cap assembly T 12A will come factory assembled for all model numbers ending in TRMTC When ready to remove Test Cap and install trim follow the instructions below 2 Remove test cap from valve FIGURE 4 1 3 If system is dirty flush valve 4 Thread flow control spindle and cap as...

Page 4: ...X A B C K K L G H I J D E F G H I D E F M M O Q P R S T U W V N EF 109 Order in line vacuum breaker EF 109 for hand shower systems without dual checks 7 Parts Breakdown Notes 1 Append appropriate suffix for premium finish 2 Append appropriate flow rate to showerhead or hand shower for low flow 3 Apply a bead of silicone around the perimeter of all shower trim installed flush to the finished wall L...

Page 5: ...nting screws FIGURE 9 1 FIGURE 9 1 FIGURE 9 2 4 Install handle to diverter valve Secure with star washer set screw and plug button FIGURE 9 4 3 Install dome cover and lock nut to valve by turning clockwise FIGURE 9 3 FIGURE 9 3 1 Attach shower arm and flange to shower pipe Turn clockwise to tighten FIGURE 10 1 2 Install showerhead to shower arm Turn clockwise to tighten FIGURE 10 2 3 Install tub s...

Page 6: ...ption Place mounting plate in position mark and drill 1 8 pilot holes into stud 3 Install mounting plate Secure with two screws Replace cradle mount cover FIGURE 11 3 Note Mounting plate center tabs must be horizontal for installation FIGURE 11 5 1 3 FIGURE 11 2 2 1 3 FIGURE 11 3 2 5 Install wall elbow and flange to recessed pipe fitting Turn elbow clockwise to tighten FIGURE 11 5 FIGURE 11 6 FIGU...

Page 7: ... 2 to divert to function 2 FIGURE 13 2 3 Turn handle to position 3 to share functions 1 and 2 FIGURE 13 3 FIGURE 13 1 FIGURE 13 2 FIGURE 13 3 14 Operation Triple Outlet Diverter Control 1 Cartridge is factory set to divert to function 1 FIGURE 14 1 2 Turn handle to position 2 to divert to function 2 FIGURE 14 2 3 Turn handle to position 3 to divert to function 3 FIGURE 14 3 FIGURE 14 1 FIGURE 14 2...

Page 8: ...emicals including lead which is known to the state of California to cause cancer birth defects or other reproductive harm For more information go to www P65Warnings ca gov 15 Troubleshooting Chart Problem Cause Solution Finish is spotting Elements in water supply may cause water staining on finish Clean finished trim area with a soft cloth using mild soap and water or a non abrasive cleaner and th...