Symmons SCOT SLC-6000 Series Operation & Maintenance Manual Download Page 3

Installation with MAXLINE

 Thermostatic Mixing Valve

Installation (adjustments)

2)  

To limit temperature

 loosen set 

screw (B), remove handle (A), loos-

en nut (D) and turn cartridge stem 

(H) to desired maximum tempera-

ture (110

°

F recommended). Turn 

limit stop washer (E) clockwise until 

a positive stop is reached against 

back of faucet.  Reassemble faucet 

reversing above procedure.   

5

2

B

A

1

3

C

D

4

E

F

H

*

3)  

For reverse operation

 (in back to 

back installations or when hot sup-

ply is on the right) loosen set screw 

(B), remove handle (A), nut (D) and 

limit stop washers (E) & (F). Turn 

cartridge stem (H) 180

° 

so green 

marking* is facing toward front of 

faucet.        Adjust temperature limit 

(see step 2).   Reassemble faucet, 

reversing the above procedure.

2

B

A

1

3

C

Note:  

When setting MAXIMUM cycle time, 

you MUST maintain at least 5 timing wash-
ers (C) so as not to exceed .25 gal/cyl at 60 
psi (per ASME A112.18.1)

Maintenance

2

B

A

1

3

C

D

H

E

4

5

6

Note:  

Faucet will operate from the full 

cold position to the maximum hot tem-
perature that has been set.

2

B

A

1

3

C

1)  Loosen set screw (B), remove      

handle (A) and remove cycle timing   

washers (C).

2)  Remove nut (D), limit stop washers 

(E) & (F) and cartridge housing (G).

3)  Remove cartridge (H) and inspect 

for debris. Replace cartridge if nec-

essary. Reassemble faucet reversing 

procedure outlined in Steps 1 & 2. 

1

2

D

E

F

3

G

H

1)  Faucet is factory set to shortest cycle 

time with 7 cycle timing washers (C). 

To increase time

, loosen set screw (B), 

remove handle (A) and remove 

one or more of the washers.  

To reduce time

, add washers. 

Reassemble faucet reversing above 

procedure. 

MAXLINE THERMOSTATIC

MIXING VALVE

(8210CK)

COLD WATER

BYPASS TEE

FITTING

SCOT FAUCET

(SLC-6000)

TO HOT

WATER SUPPLY

DO NOT 

REMOVE TAPE

TO COLD

WATER SUPPLY

FIGURE 1

SLC-6000-ML

TEMPERED

WATER LINE

COLD

WATER LINE

VALVE 

OUTLET

Important:  

DO NOT REMOVE tape on copper 

tubing.

For applications using MAXLINE thermostatic mix-

ing valve.

1)  Turn off water supplies.

2)  Connect tempered water line of faucet to thermo-

static mixing valve outlet (see Figure 1 for piping 

reference).

Note:

 Valve and cold water bypass use compres-

sion 

fittings (fittings not supplied).

3)  Connect cold water line of faucet to the cold wa-

ter     bypass using supplied tee fitting.

4)  Connect copper tubing from cold water bypass 

tee fitting to thermostatic mixing valve.

5)  Connect hot water supply to thermostatic mixing 

valve and cold water supply to cold water bypass 

tee fitting.

6)  Remove aerator from faucet. Turn handle to full 

cold position. Open supply, holding down handle 

for 10 seconds. Rotate handle to full hot position, 

open supply and repeat above procedure.  Hold 

down handle and rotate from left to right to flush 

lines to prevent foreign matter i.e. copper chips, 

sand, stones, etc. from clogging and possibly 

damaging the sealing surfaces of the faucet car-

tridge. 

Summary of Contents for SCOT SLC-6000 Series

Page 1: ...deck plate G Grid drain IPS 1 2 male IPS connections OFG Offset grid strainer ASME A112 18 1 CSA B125 1 NSF ANSI 61 9 NSF ANSI 372 Dimensions Measurements A Ø 1 7 8 48 mm B 3 3 4 95 mm C Deck Thickness Ref Min 1 2 13 mm Max 1 25 mm D 1 3 8 35 mm E 2 1 8 54 mm F 2x Hole Size Ø 1 2 13 mm G Hole Size Ø 1 1 4 32 mm H 11 279 mm I 4 102 mm J 5 3 4 146 mm K 1 1 2 38 mm L 2 1 4 57 mm M 1 1 8 29 mm N 3 5 8...

Page 2: ...ession nuts U and ferrules V from supply stops Re tain for installation to faucet copper tubing Ensure washer is in place before installing Install check screen assemblies W to supply stops 2 Install faucet I threaded rods M mounting gasket Q and 3 8 cop per tubing P to deck surface M 1 3 R 2 S T 4 3 Place mounting brackets R and spacers S onto threaded rods M Secure hardware by tightening mountin...

Page 3: ...1 2 1 2 D E F 3 G H 1 Faucet is factory set to shortest cycle time with 7 cycle timing washers C To increase time loosen set screw B remove handle A and remove one or more of the washers To reduce time add washers Reassemble faucet reversing above procedure MAXLINE THERMOSTATIC MIXING VALVE 8210CK COLD WATER BYPASS TEE FITTING SCOT FAUCET SLC 6000 TO HOT WATER SUPPLY DO NOT REMOVE TAPE TO COLD WAT...

Page 4: ...unter Supply housing o rings worn Replace housing o rings G1 Faucet bleeding between hot and cold LL 71B check screens NOT in stalled Two chrome plated 3 8 check screens are supplied with every faucet and MUST be installed Faucet bleeding between hot and cold LL 71B check screens ARE in stalled Replace check springs K L Handle is loose Set screw has loosened Tighten set screw B Handle is sticking ...

Reviews: