Symmons SCOT SLC-6000 Series Operation & Maintenance Manual Download Page 2

Replacement Parts

Description

Part Number

A
B

Handle

Set Screw

RL-290

B

Set Screw

LL-27

C

Cycle Timing Washers (7)

LL-28

D

E
F

Nut

Limit Stop Washer

Limit Stop Washer, Fixed

RL-268

G

Upper Housing

LL-3N

G1

Upper Housing O-rings (3)

LL-48

G1

H3
H4
H5

H10

Upper Housing O-rings (3)

Cartridge O-ring
Cartridge O-ring

Guide O-ring

Piston Quadring

RL-272

H

Cartridge

Quick Closing Cartridge

LL-1A
LL-1B

H1

H6

Control Spindle Kit

Piston Assembly

RL-266

H2

Thrust Washer

LL-35

H6

Piston Assembly

LT-4AA

H11

Piston Spring/Cylinder

RL-267

J

0.5 gpm Vandal Resistant 

Aerator Kit with Key

RL-292

K

L

Check

Spring

RL-269

R

S
T

Mounting Bracket

Spacer

Mounting Nut

SPF-KIT

W

Check/Screen Assembly

LL-71B

X1, X2

8" Deck Plate Assembly

RL-291

Y

Washer

TMX-06527-1

Parts Breakdown

B

A

C

D

E

F

G

H

I

J

K

M

L

O

N

P

Q

R

S

T

U

V

W

DO NOT 

REMOVE TAPE

X1

X2

Y

Installation / Tools Required

Water lines MUST be thoroughly flushed BEFORE and AFTER installing the faucet to prevent foreign matter i.e. 
copper chips, sand, stones, etc. from clogging and possibly damaging the sealing surfaces of the cartridge.

Notes:  

1) Recommended minimum operating water supply pressure is 40 psi.

2) Supply stop valves must have 3/8" O.D. compression outlet.

1

2

U

V

W

1

2

3

3

Y

1)  Remove compression nuts (U) and 

ferrules (V) from supply stops. Re-
tain for installation to faucet copper 
tubing. Ensure washer is in place 
before installing. Install check/screen 
assemblies (W) to supply stops.

2)  Install faucet (I), threaded rods (M), 

mounting gasket (Q), and 3/8" cop-
per tubing (P) to deck surface.

M

1

3

R

2

S

T

4

3)  Place mounting brackets (R) and 

spacers (S) onto threaded rods (M). 
Secure hardware by tightening 
mounting nuts (T) clockwise.

3

3

1

2

U

P

V

W

2

A

J

1

3

4

5)  Remove aerator (J). Turn handle (A) 

to full cold position. Open supply, 
holding down handle for 10 seconds. 
Rotate handle to full hot position, 
open supply and repeat above 
procedure. Hold down handle and 
rotate from left to right to flush lines 
completely.

6) 

 

After faucet has been operated 
through a number of cycles, and sup-
ply water temperature is at desired 
levels, adjustments to these features 
can be made (see page 4).

I

M

Q

P

Important:  

DO NOT REMOVE 

tape on copper tubing.

CAP AND CARTRIDGE ASSEMBLY

G1

H6

H11

G

H

H3

H4

H5

H7

H8

H9

H10

H12

H13

H14

H1

H2

Adjustable Wrench

Allen Wrench: 2.5 mm

Phillips Head Screwdriver

4)  Connect compression nuts (U) and 

ferrules (V) to copper tubing (P). 
Carefully bend copper tubing (P) to 
meet check/screen assemblies (W).  
Attach compression nuts to check/
screen assemblies.

7)  

Optional 8" Deck Plate:

  Remove 

threaded rods (M) from faucet (I).  
Install two screws (X2) through    
bottom of deck plate (X1) into           
faucet (I).  Install faucet and deck 
plate to deck surface.

3

3

I

M

1

2

X2

X1

I

Summary of Contents for SCOT SLC-6000 Series

Page 1: ...deck plate G Grid drain IPS 1 2 male IPS connections OFG Offset grid strainer ASME A112 18 1 CSA B125 1 NSF ANSI 61 9 NSF ANSI 372 Dimensions Measurements A Ø 1 7 8 48 mm B 3 3 4 95 mm C Deck Thickness Ref Min 1 2 13 mm Max 1 25 mm D 1 3 8 35 mm E 2 1 8 54 mm F 2x Hole Size Ø 1 2 13 mm G Hole Size Ø 1 1 4 32 mm H 11 279 mm I 4 102 mm J 5 3 4 146 mm K 1 1 2 38 mm L 2 1 4 57 mm M 1 1 8 29 mm N 3 5 8...

Page 2: ...ession nuts U and ferrules V from supply stops Re tain for installation to faucet copper tubing Ensure washer is in place before installing Install check screen assemblies W to supply stops 2 Install faucet I threaded rods M mounting gasket Q and 3 8 cop per tubing P to deck surface M 1 3 R 2 S T 4 3 Place mounting brackets R and spacers S onto threaded rods M Secure hardware by tightening mountin...

Page 3: ...1 2 1 2 D E F 3 G H 1 Faucet is factory set to shortest cycle time with 7 cycle timing washers C To increase time loosen set screw B remove handle A and remove one or more of the washers To reduce time add washers Reassemble faucet reversing above procedure MAXLINE THERMOSTATIC MIXING VALVE 8210CK COLD WATER BYPASS TEE FITTING SCOT FAUCET SLC 6000 TO HOT WATER SUPPLY DO NOT REMOVE TAPE TO COLD WAT...

Page 4: ...unter Supply housing o rings worn Replace housing o rings G1 Faucet bleeding between hot and cold LL 71B check screens NOT in stalled Two chrome plated 3 8 check screens are supplied with every faucet and MUST be installed Faucet bleeding between hot and cold LL 71B check screens ARE in stalled Replace check springs K L Handle is loose Set screw has loosened Tighten set screw B Handle is sticking ...

Reviews: