Care and Cleaning

Trouble Shooting Chart

Problem

Cause

Solution

Water flow is less than normal.

Screen in cartridge is dirty or 

clogged.

1) Remove cartridge and clean un-

der running water.

2) Remove cartridge and clean in

household vinegar or replace by

ordering cartridge replacement kit.

Water continues to run colder than

original temperature setting.

Check valve is not completely 
sealed allowing cold water to mix 

with hot.

Remove screen/check valve and

clean under running water.

Valve is leaking around the cap

retaining nut area.

Water leaking from o-ring seal.

Replace cartridge by ordering 

cartridge replacement kit.

Tempered hot water temperature is 

not hot enough.

Hot water supply into valve is not 

10°F (5.55°C) above desired set 

point temperature. Temperature 

setting it to low.

Increase hot water supply

temperature into valve. Reset 

temperature according to "Setting 

valve temperature" instructions.

Remove cartridge and clean valve body in household vinegar to remove corrosive mineral build up. Rinse 
under running hot water to ensure valve is free of foreign debris.