Symmons Maxline 8210CK Operation & Maintenance Manual Download Page 5

5

Operation & Maintenance

Initial 30 Day Inspection

Inspect cartridge within 30 days of initial operation.
If inspection determines that your water system is
causing deposits and foreign matter to build-up,
then adjust cartridge maintenance accordingly.

Cartridge Replacement

1) Shut off hot and cold water supplies to valve.

2) Remove screw and cap. This will expose the 
    cartridge stem and cartridge retaining nut.

3) Remove retaining nut by turning counter-clockwise
    with adjustable wrench.  Grasp cartridge with 
    pliers and remove from body by pulling straight
    out. A slight rocking rotation may be required to
    loosen while removing.

4) Lubricate cartridge o-rings with a small amount of
    silicone lubricant prior to reinstalling. Insert replace  
    ment cartridge into valve body, applying enough   
    force to ensure cartridge is fully seated. Install 
    retaining nut back onto valve body.

5) Refer to “Setting Valve Temperature” section (pg.3)
    to properly set valve to desired temperature.

Seasonal Use

If valve is used seasonally, such as in schools or 
campgrounds, then perform the following steps to 
avoid damage caused by freezing water when valves
are not in use:

1) Shut off hot and cold water supplies.

2) Remove valve cartridge and drain all water.

3) Drain water from the supply lines and valve body.

Service Instructions

Cleaning screens & check valves:

1) Shut off hot and cold water supplies.

2) To clean screens leave cap installed. Remove
    retaining nut and remove cartridge. Clean debris
    from screens and body. Apply silicone lubricant to
    O-rings and reinstall.

3) To Replace the check valves, remove the supply 
    lines and remove check valves from center body.
    Reinstall new check valves. Reconnect supply
    lines.