Symmons Allura S-7601-STNRP Installation And Service Instructions Manual Download Page 2

Page 2

 Installation Instructions

 ■ Place handle over end of 

control 

spindle stem

.    Tighten 

packing 

nut

 for positive frictional 

resistance as handle is rotated 

from shutoff position across 

adjustment range.

8) 

Flush system and check 

for leaks

 ■ Turn valve to the warm position 

and run for a few minutes.

 ■ If system is dirty, remove valve 

spindle in valve to ensure 

proper flushing. See service 

instructions. 

Note:

   Do not install positive 

shut-off devices on valve 

outlet or devices that do not 

allow the valve to flow at least 

1 GPM at 50 psi inlet pressure.

 Rough-in Installation

Control valve assembly, piping 

and fittings

Reference as required: 

Page

Visual Guide ...................................

1

Dimensions illustration ................

4

1) 

Determine wall thickness

 

Determine type of wall and wall 

thickness where valve will be 

mounted as follows:

Fiberglass or acrylic walls:

Thickness = 

1/2” (13 mm)

 or less

Dry wall, plaster, or other type 

walls:

Thickness = more than 

1/2" 

(13mm)   

Skip ahead to step 3

2) 

Attach mounting plate

Seat plate against valve  assembly.

3)  Attach protective shield

Attach plastic protective shield 

by snap fitting over end of valve 

spindle as shown in Figure 2. 

4) 

Install control valve

Install through cutout hole in wall 

as specified in Figure 2 below and 

Dimensions illustration on page 4.

5) 

Install piping and fittings

Piping and fittings not supplied.

Showerhead (S on valve)

Pipe from outlet port on valve 

marked 

S

 to showerhead 

mounting arm location.

Hot & Cold Supply (H & C)

Pipe hot water supply to valve 

input marked 

H

 and cold water 

supply to valve input marked 

C

.

6) 

Remove protective shield

Remove shield snap fitted over 

the end of valve spindle after 

valve is securely installed.

7)  Adjust valve packing nut

 ■ Turn hot & cold supplies on.

Valve will not operate unless 

both hot and cold water supply 

pressure are turned on. 

Figure 1  

Mounting plate

 

Figure 3  

Limit stop screw

 

Figure 2  

Mounting valve

wall

Temp Limit

stop screw

packing nut

control

spindle

stem

wall cutout hole size

3-1/2" (89 mm) min

       4" (102 mm) max

Finished wall must be

flush with back side of 

protective shield surface

finished wall

Dry wall, plaster or other type wall

   

1/2" (13 mm) or greater

Protective shield

"snap on-off" 

(required when

 mounting plate

 is not used)

2-3/8" ± 1/2"

(60 mm ±13 mm)

pipe centerline  

to finished wall

 wall cutout hole size

3-1/2" (89 mm) min

       4" (102 mm) max

finished

 wall

Ensure valve’s

mounting plate

is flush against

inner wall

Walls for using T-177 mounting plate

 

Fiberglass or acrylic walls (required)

 

Plaster or other type walls (optional)

    1/16" (2 mm) min  

 1/2" (13 mm) max

p/n T-176 p/n T-177

Protective shield

When mounting plate is used, 

then shield is optional for 

protecting end of valve during 

installation. 

 

"snap on-off"

Summary of Contents for Allura S-7601-STNRP

Page 1: ...h Ordering Replacement Parts Systems with optional satin finish append STN 3 letter finish code to part numbers with an asterisk Temptrol control valve S 4002 BODY RTS 032 T 19 300S Temp limit screw a...

Page 2: ...llustration on page 4 5 Install piping and fittings Piping and fittings not supplied Showerhead S on valve Pipe from outlet port on valve marked S to showerhead mounting arm location Hot Cold Supply H...

Page 3: ...ximum position resulting in excessive hot water discharge temperatures Place handle on control spindle and open valve to maximum desired temperature Turn stop screw clockwise until it seats Reference...

Page 4: ...tional Protective shield usage optional for protection only 2 Dry wall plaster or other type walls 1 2 or greater Protective shield attached to valve spindle to locate position 3 Dimensions subject to...

Page 5: ...her retainer cold washer spindle cap gasket Control spindle washer repair kit TA 9 Parts Assembly Temptrol Tub Shower Control Valve S 46 2 BODY Valve Replacement Parts and Special Tools TA 4 Hot and c...

Page 6: ...embly Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 Phone 800 796 6667 Fax 800 961 9621 Copyright 2017 Symmons Industries Inc symmons com gethelp symmons com ZV 1092R REV A 110917 Trouble...

Page 7: ...un plomero licenciado Gu a visual sistema de ducha Allura S 7601RP S 7601 STNRP N meros de modelos S 7601RP sistema de ducha con acabado est ndar de cromo S 7601 STNRP sistema de ducha con acabado de...

Page 8: ...a de control Instale a trav s del hoyo cortado en la pared como se especifica en la figura 2 debajo de la ilustraci n de la dimensi n en la p gina 4 Cabezal de ducha S en la v lvula Tuber a desde el p...

Page 9: ...arga de agua caliente Coloque la manija en la boquilla del control del eje y abra la v lvula a la temperatura m xima deseada Gire el tornillo de tope de L mite de temperatura en sentido horario hasta...

Page 10: ...erminada 2 1 2 di metro 64 mm Notas tambi n refi rase a p gina 2 figura 2 para ver detalles 1 Paredes para utilizar la placa de montaje T 177 MP La pared es de 1 16 2 mm m n 1 2 13 mm m x Paredes de f...

Page 11: ...e arandela de agua caliente arandela de agua caliente ret n de arandela de agua fr a arandela de agua fr a boquilla junta del tap n Kit de reparaci n de arandela del eje de control TA 9 Ensamblaje de...

Page 12: ...usa Soluci n La v lvula no deja pasar el agua Tanto los suministros de agua caliente como de agua fr a no se activan Active ambos suministros La v lvula no funcionar a menos que la presi n del agua ca...

Reviews: