140
TimeSource 3000
TL1 Reference
097-72000-02 Issue 6: October 2003
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
4
Enter Equipment (cont’d)
The parameters which can be entered in the <spec block> are listed below. For any specific
<aid> entered in a command, only certain parameters are valid. For each valid parameter,
choose the appropriate value of "b" from the "b Value" column. When entering multiple
parameters, separate the parameters with commas.
Example to set an input to be monitored, but not ensembled:
ENT-EQPT:[<tid>]:RO-A:<ctag>;
Example to set an input to be monitored and ensembled:
ENT-EQPT:[<tid>]:RO-A:<ctag>:::ENSEMBLER=ALW;
Response Format:
<sid> <date> <time>
M <ctag> COMPLD
/*LINK:<link>,CMD:<command>*/
;
Aid
Parameter
Value
Description
RO-a
ENSEMBLER=b
b=ALW
Remote oscillator is monitored and
ensembled
b=INH
Remote oscillator is monitored, but not
ensembled
SPAN-a
ENSEMBLER=b
b=ALW
Span is monitored and ensembled
b=INH
Span is monitored, but not ensembled
Summary of Contents for TimeSource 3000
Page 1: ...TimeSource 3000 GPS Primary Reference Source 097 72000 02 Issue 6 October 2003 ...
Page 47: ...3 Chapter Installation This chapter provides the steps required for installation and power up ...
Page 107: ...Chapter 4 TL1 Reference This chapter provides information for using the TL1 language ...