166 TimeCreator 1000 User’s Guide
097-93100-01 Revision C – February, 2010
Appendix A Alarms, Events and SNMP Traps
SNMP Traps
21
trapInputActive
(id = 31)
IOC <#> has
selected GPS as
reference
IOC <#> has
selected DTI Port
<#> as reference
IOC <#> has
selected BITS Port
<#> as reference
IOC <#> has
de-selected GPS as
reference
IOC <#> has
de-selected
DTI Port <#> as
reference
IOC <#> has
de-selected
BITS Port <#> as
reference
trapID:
INPACTV
nonalarm
trapAID1:
0: GPS
1: DTI A
2: DTI B
3: BITS 1
4: BITS 2
trapAID2: 1 or 2,
IOC module id
trapState:
clear (1),
set (2)
trapValue: n/a
22
trapPortTesting
(id = 33)
Port <#> has
transitioned into Test
Mode
trapID:
OUTTEST
nonalarm
trapAID1: port #
trapAID2:
n/a
trapState:
set (2)
trapValue: n/a
23
trapAutoReset
(id = 37)
IOC <#> Module
auto reboot
trapID:
AUTORST
nonalarm
trapAID1: 1 or 2,
IOC module id
trapAID2:
n/a
trapState:
set (2)
trapValue: n/a
Table A-9. TimeCreator Events Traps - Additional Details (Continued)
OID
Index
(y)
Trap OID Name
Description
Bindings
Severity