164 TimeCreator 1000 User’s Guide
097-93100-01 Revision C – February, 2010
Appendix A Alarms, Events and SNMP Traps
SNMP Traps
11
trapIOCOffline
(id = 15)
IOC <#> is disabled
IOC <#> is enabled
trapID:
CARDOFF
nonalarm
trapAID1: 1 or 2,
IOC module id
trapAID2:
n/a
trapState:
clear (1),
set (2)
trapValue: n/a
12
trapPortWarmup
(id = 18)
Port <#> has
transitioned into
Warm-up Mode
trapID:
CLTWARM
nonalarm
trapAID1: port #
trapAID2:
n/a
trapState:
set (2)
trapValue: n/a
13
trapPortFreerun
(id = 19)
Port <#> has
transitioned into
Free-run Mode
trapID:
CLTFREE
nonalarm
trapAID1: port #
trapAID2:
n/a
trapState:
set (2)
trapValue: n/a
14
trapPortFasttrack
(id = 20)
Port <#> has
transitioned into
Fast-lock Mode
trapID:
CLTFSTRK
nonalarm
trapAID1: port #
trapAID2:
n/a
trapState:
set (2)
trapValue: n/a
15
trapPortNormaltrack
(id = 21)
Port <#> has
transitioned into
Normal Mode
trapID:
CLTNMTRK
nonalarm
trapAID1: port #
trapAID2:
n/a
trapState:
set (2)
trapValue: n/a
Table A-9. TimeCreator Events Traps - Additional Details (Continued)
OID
Index
(y)
Trap OID Name
Description
Bindings
Severity