098-00208-000 Revision A – February, 2010
TimeAnalyzer 7x00 User’s Guide 119
Chapter 6 Maintenance and Troubleshooting
Troubleshooting
Ethernet Port 2
ETH2 port
link/activity
indicator
ETH2
Green - Link has been
established
n/a
Flashing Green - Link activity
n/a
Off - Link has not been
established
Check the cable connections and
SFP connections.
Verify that interface is enabled.
with “show ip config ioc1”
command
Verify that SFP connector models
are recommended and supported.
Check that either Ethernet Auto
Negotiation is enabled or that
speed has been set to a
compatible level with the
connecting network element with
“show eth-config” command.
Make sure that only full-duplex
network devices are used. The
TP5000 does not support
half-duplex devices, such as
hubs, for PTP connections.
Local Oscillator
State
Indicates the
current mode of
operation of the
LO servo
HOLD
Off - Oscillator is operating in
Locked mode
n/a
Amber - Oscillator is operating in
Holdover or Acquire
modes
Check the reference input source
to verify that it is connected and
operational.
Flashing Amber - Oscillator is
operating in Warm-up
mode
Typical warm-up time for the
Active card is:
Quartz 30
40 minutes
Rubidium
50
60 minutes
Standby IOC starts locking to
Active IOC after Active IOC
enters normal track. Allow an
additional ~20 minutes for
Standby card to completes
warm-up.
Table 6-3. LED Conditions for the IOC Card - TP5000 Probe Module (Continued)
Indicator
Label
Description
Corrective Action